Brochure
11
Table 6 - Becker RPDA Actuator Selection Table
T-Ball
Valve Size
500 (3447 kPa) = ΔP 1000 (6895 kPa) = ΔP 1500 (10342 kPa) = ΔP
Double Acting Double Acting Double Acting
2” (50 mm) 5D 5D 5D
3” (80 mm) 5D 5D 6D
4” (100 mm) 6F 6F 6F
6” (150 mm) 8F 8F 8H
8” (200 mm) 10F 10F 10H
10” (250 mm) 10H 10H 10L
12” (300 mm) 10L 10L 12L
Temperature -20° F (-28.9° C) 100 psig (689 kPa) Power Gas
T-Ball
Valve Size
500 (3447 kPa) = ΔP 1000 (6895 kPa) = ΔP 1500 (10342 kPa) = ΔP
Double Acting Double Acting Double Acting
2” (50 mm) 5D 5D 5D
3” (80 mm) 5D 5D 6D
4” (100 mm) 6F 6F 6F
6” (150 mm) 8F 8F 8H
8” (200 mm) 10F 10F 10H
10” (250 mm) 10H 10H 10L
12” (300 mm) 10L 10L 12L
Temperature -20° F (-6.7° C) 100 psig (689 kPa) Power Gas
T-Ball
Valve Size
500 (3447 kPa) = ΔP 1000 (6895 kPa) = ΔP 1500 (10342 kPa) = ΔP
Double Acting Double Acting Double Acting
2” (50 mm) 5D 5D 5D
3” (80 mm) 5D 5D 6D
4” (100 mm) 6F 6F 6F
6” (150 mm) 8F 8F 8H
8” (200 mm) 10F 10F 10H
10” (250 mm) 10H 10H 10L
12” (300 mm) 10L 10L 12L
Temperature -20° F (-28.9° C) 125 psig (861 kPa) Power Gas
T-Ball
Valve Size
500 (3447 kPa) = ΔP 1000 (6895 kPa) = ΔP 1500 (10342 kPa) = ΔP
Double Acting Double Acting Double Acting
2” (50 mm) 5D 5D 5D
3” (80 mm) 5D 5D 6D
4” (100 mm) 6F 6F 6F
6” (150 mm) 8F 8F 8H
8” (200 mm) 10F 10F 10H
10” (250 mm) 10H 10H 10L
12” (300 mm) 10L 10L 12L
Temperature -20° F (-6.7° C) 125 psig (861 kPa) Power Gas
1. Contact GE representative for valve sizes over 12” bore.
2. T-Ball valves are comprised of the following: FPCV-TO, FPBV, QTCV-T1, QTCV-T2, and QTCV-T4
3. For power gas pressures greater/less than 100 psig (689 kPa) contact GE.
4. For higher ΔP applications contact GE representative.
5. Power Gas = P
supply
- P
discharge
for applications that utilize Bleed to Pressure System
™
Feature.
Choose the Perfect Rotary Control
Valve for your Application
FPCV-T0 Series Full Port Control Valve:
High turndown capability up 100:1
High pressure drop shutoff capability to
Class VI
QTCV-T1 Series Quiet Trim Control Valve:
Noise attenuation up to 7 dBA
High turndown capability up to 200:1
High pressure drop shutoff capability to
Class V
QTCV-T2 Series Quiet Trim Control Valve:
Noise attenuation up to 17 dBA
High turndown capability up to 300:1
High pressure drop shutoff capability
to Class IV
QTCV-T4 Series Quiet Trim Control Valve:
Noise attenuation up to 25 dBA
High turndown capability up to 200:1
High pressure drop shutoff capability to
Class IV