Installation Guide
Connection Congurations
3
For information on A, B, C, D, see Steps 4, 5 and 6.
WARNING/AVERTISSEMENT
Risk of electrical shock. Ensure that all connection points are sealed for damp location using the appropriate method per
the NEC or local electrical code. Risque de choc électrique. S’assurer que les points de raccordements sont scellés pour
emplacement humide en employant une méthode permise par le NEC ou par le code électrique local.
One End Set (Right and Left) &
One Center LED Light
LED DRIVER
WHITE (NEUTRAL)
BLACK (LINE)
SWITCH
BR
BW
RB
G
CENTER LED LIGHT
A
C
BR
LEFT END LED LIGHT
BR
RIGHT END LED LIGHT
D
Occupancy Sensor
Gray Purple
Note: LED Lights are polarity insensitive
B
C
Terminal Block
(AC Source)
5
Multiple LED Light’s electrical input should be in parallel connection to an LED driver’s output as shown by
the example wiring diagram below. Refer to “Maximum LED Driver Loading” table to determine maximum
number of LED lights per LED driver.
Driver Wire
Connector Cavities
39-01-4030 (AC)
Cavity 1 - Line 1 (Black)
Cavity 2 - Earth Ground (Green)
Cavity 3 - Neutral or Line 2 (White)
39-01-4046 (DC)
Cavity 1 - Output DC (+) (Red)
Cavity 2 - Output DC (-) (Black)
Cavity 3 - Dimming (Purple)
Cavity 4 - Dimming (Gray)