Data Sheet
07.13 GFA-1052B
©2012 GE Intelligent Platforms, Inc. All rights reserved.
All other brands or names are property of their respective holders.
Specifications are subject to change without notice.
GE Intelligent Platforms Contact Information
Americas: 1 877 429 1553 Global regional phone numbers are listed by location on our web site at
defense.ge-ip.com/avionics-contacts
defense.ge-ip.com/avionics
About GE Intelligent Platforms
GE Intelligent Platforms is a division of GE that offers software, control systems, services, and expertise
in automation and embedded computing. We offer a unique foundation of agile and reliable technology
providing customers a sustainable competitive advantage in the industries they serve, including energy,
water, consumer packaged goods, oil and gas, government and defense, and telecommunications. GE
Intelligent Platforms is headquartered in Charlottesville, VA. For more information, visit www.defense.
ge-ip.com.
R15-EC – RoHS Dual Port MIL-STD-1553 ExpressCard Interface
Ordering Information
R15-EC-G2-1D MIL-STD-1553 single-function, single dual-redundant channel, 32-bit FW
R15-EC-G2-1M MIL-STD-1553 multi-function, single dual-redundant channel, 32-bit FW
R15-EC-G2-1D MIL-STD-1553 single-function, two dual-redundant channel, 32-bit FW
R15-EC-G2-2M MIL-STD-1553 multi-function, two dual-redundant channel, 32-bit FW
Optional Hardware
-W suffix IRIG
-R suffix Operating case temperature range not to exceed -40° C. to +65° C
Optional Software
BusTools/1553 MIL-STD-1553 Bus Analysis & Data Logging software for Windows
LV-1553 Lab/View support for MIL-STD-1553
Specifications
Physical
• ExpressCard/54 extended module
Environmental
• Card operating temperature: 0° C to +55° C
• Extended temperature: -40° C to +65° C available
(operating case temperature range not to exceed -40°
C to +65° C)
• Storage temperature: -50° C to +100° C
• Relative humidity: 5 to 90% (non-condensing)
Software
• API – Includes high-level API libraries for Windows 7
Vista, XP, NT, Linux, Solaris and VxWorks
– Source code API library provided
– Hardware interrupts supported
• GUI – Optional BusTools/1553 GUI bus analysis,
simulation and data logging software
• LV-1553 – LabVIEW support for MIL-STD-1553
Connections
• Transition cabling provided via robust 36-pin
Champ type connector
• Input and output triggers
• Two bi-directional avionics discretes
• Transformer coupling
• IIRIG-B Rec (AM or DC/TTL), Gen (DC/TTL) standard
• Fixed output voltage
Multi-function Operational Modes
• Simultaneous BC, 31 RTs and BM
Single-function Operational Modes
• BC or 31 RTs or BM
Thermal Design Power (2 channels at 90% duty cycle)
• 1.75 W max
On-board Dual-port RAM
• 1 Mbyte per channel
Timing
• Independent 64-bit, 25ns message time-
tagging per channel
• Time can be programmed via the host or by
a 1553 trigger
• All timers can be synchronized to 0 via the
host
• Timers can independently use IRIG time
• IRIG-B receiver (AM or DC/TTL) and gener-
ator (DC/TTL)
Description
Bus Controller
• Programmable control over:
– Major and minor frame content and timing
– Intermessage gap times
– Response time-out and late response
• Modify messages, data or setup while card is running
• Multiple data buffers
• Insert aperiodic messages into a running BC list
• “Oneshot“ mode for simplified BC operation
• Conditional message sequencing based on real-time
message data or status
• Selectable interrupt generation and status messages
– Full range of system conditions
– All detected errors
• Full error detection
– Invalid word – Late response
– Bit count error – Early response
– High word – No response
– Low word – Incorrect RT address
– Inverted sync – Parity error
– Manchester
• Extensive programmable error injections (on a per
word basis)
• Synchronize BC operation to external time source
• 64-bit nanosecond resolution time tagging on BC,
RT and BM
• Virtually unlimited time stamping
Remote Terminal
• Multiple RT simulation (up to 31 RTs)
• Programmable message content (linked
message buffers)
• Modify data, status words or setup while card
is running
• Programmable error injection (on a per word basis)
• Interrupts can be generated on a per message basis
upon End of Message and error conditions
Bus Monitor
• Capture 100% fully loaded bus traffic with:
– Time-tagging – Error status
– Word status – Message status
– RT response time
• Interrupts can be selected by RT / SA / WC
• Extensive filtering and triggering options
– By individual RT/subaddress
– Transmit, receive or broadcast mode codes
– Internal or external triggering
– Trigger output on user specified data
• Real-time bus playback with RT edit mode