Installation Guide

2 C
CUTOUT FOR DOUBLE OVENS (2 THERMAL
OVENS)
NOTE: If the cabinet does not have a front frame and the sides are less than ¾” (1.9 cm) thick,
shim both sides equally to establish the cutout width.
Dim. Description
30” Double Oven with
Pedestal
30” Double Oven
without Pedestal
A Cabinet Width 30” (76.2 cm) 30” (76.2 cm)
B Cutout Width 28
1
»2” (72.4 cm) min.
28
5
»8” (72.7 cm) max.
28
1
»2” (72.4 cm) min.
28
5
»8” (72.7 cm) max.
C Cutout Height 51
13
»16” (131.6 cm) min.
51
15
»16” (131.9 cm) max.
50 ¼” (127.64cm)
D Clearance from cutout - side edges*
11
»16” (1.75 cm)
11
»16” (1.75 cm)
E Clearance to Adjacent Corners,
Drawers, Walls, etc., When Door
Is Open
31
1
»8” (77.8 cm) min. 31
1
»8” (77.8 cm) min.
F Clearance from cutout - top* 1” (2.5 cm) min.
(1
1
»4” (3.2 cm) for PT9550,
ZET2S and ZET2P)
1” (2.5 cm) min.
(1
1
»4” (3.2 cm) for PT9550,
ZET2S and ZET2P)
G Clearance from cutout - bottom* 1
1
»4” (3.2 cm) 1
1
»4” (3.2 cm)
H Junction Box Location 9
1
»2” (24.1 cm) max. right
side only
9
1
»2” (24.1 cm) max. right
side only
J Height to Bottom of Junction Box 47” (119.4 cm) 47” (119.4 cm)
K Recommended Cutout Location
from Floor
12” (30.5 cm) 12” (30.5 cm)
L Door swing depth - Allow additional
clearances for installation and oven
usage
31
1
»8” (77.8 cm) min. 31
1
»8” (77.8 cm) min.
M Countertop or cabinet door protrusion
(measure if exist)
Measure “M” Measure “M”
N Gap between edge of countertop
or cabinet door to cabinet opening
If M = 0, N = 0, Otherwise
N = M + 1” (2.54 cm) min.
If M = 0, N = 0, Otherwise
N = M + 1” (2.54 cm) min.
2 D
CUTOUT FOR INSTALLATION OVER A
WARMING DRAWER
NOTE: Install the oven only with specific models listed on the label located on top of the oven.
NOTE: Additional clearances between cutouts may be required. Check to be sure the oven
supports above the Warming Drawer location do not obstruct the required interior depth and height.
When installing a Warming Drawer below a single, double, or combination oven, a separate
120V, 60 HZ, properly grounded receptacle must be installed. Refer to installation instructions
packed with the Warming Drawer for specific installation requirements.
Anti-Tip Block Against
Rear Wall Per Warming
Drawer Requirement
2" (5.1 cm)
Min.
Per Warming
Drawer
Requirement
Continue to Section 3 for Double Wall Oven with Pedestal. Otherwise, continue to Section 4.
Continue to Section 3.
31-2000252 Rev. 1 10-20 GEA
* Refers to minimum clearance required for wall oven installation and does not reflect actual product dimensions.
H
B
C
K
F
G
D
A
J
E
Junction Box
Location
(junction
box may
be located
in adjacent
cabinet)
Cutout Depth
23-1/2”
(59.7 cm) Min.
M
L
N
LH door swing shown.
RH door swings opposite.