Installation Guide
BEFORE YOU BEGIN
Read these instructions completely and 
carefully.
•  IMPORTANT — Save these 
instructions for local inspector’s use.
•  IMPORTANT — Observe all 
governing codes and ordinances.
• Note to Installer – Be sure to leave these 
instructions with Consumer.
• Note to Consumer – Keep these 
instructions for future reference.
• Skill level – Installation of this appliance 
requires basic mechanical skills and 
advanced electrical skills.
• Proper installation is the responsibility of the 
installer. 
• Product failure due to improper installation 
is not covered under Warranty.
Installation Instructions
Free-Standing and Front 
Control Electric Ranges
Questions? Call 1.800.GE.CARES (1.800.432.2737) or visit www.GEAppliances.com 
In Canada, call 1.800.561.3344 or visit www.GEAppliances.ca
MATERIALS YOU MAY NEED  TOOLS YOU WILL NEED
(UL Listed 40 AMP) 
4-Wire Cord 4’ long OR 
3-Wire Cord 4’ long
Squeeze Connector  
(For Conduit 
Installations Only)
Drill with 1/8” Bit
Safety Glasses
Adjustable Wrench
Level
Tin Snips
Tape Measure
Pliers
1/4” Nut Driver
1
 REMOVE PACKAGING MATERIALS: Failure to remove packaging 
materials could result in damage to the appliance. Remove all packing parts from oven, 
racks, heating elements and drawer. Also, remove protective film and labels on the outer 
door, cooktop and control panel. 
FOR YOUR SAFETY:
WARNING
 Before beginning 
the installation, switch power off at 
service panel and lock the service 
disconnecting means to prevent power 
from being switched on accidentally. 
When the service disconnecting 
means cannot be locked, securely 
fasten a prominent warning device, 
such as a tag, to the service panel.
If you did not receive an anti-tip bracket with your 
purchase, call 1.800.626.8774 to receive one at 
no cost. (In Canada, call 1.800.561.3344.) For 
installation instructions of the bracket, 
visit: www.GEAppliances.com. 
(In Canada, www.GEAppliances.ca.)
Anti-Tip Bracket 
Kit Included
• A child or adult can tip the range and be killed.
• Install the anti-tip bracket to the wall or floor.
• Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.
• Re-engage the anti-tip bracket if the range is moved.
• Failure to do so can result in death or serious burns
  to children or adults.
Tip-Over Hazard
WARNING
2
 PREPARE THE OPENING (FOR INDOOR USE ONLY)
See illustrations for all rough-in and spacing dimensions. The range may be placed with 0” 
clearance (flush) at the back wall and side walls of the cabinet.
2
1
»
2
”
14
1
»
2
”
2
1
»
2
”
7”
7
1
»
2
”
25”
SINGLE OVEN
DOUBLE OVEN
NOTE: Use a 4’ power cord to prevent interference 
with the storage drawer. Power cords 4
1
»
2
’ to 6’ long 
may have to be dressed to allow for proper drawer 
closing.
MINIMUM DIMENSIONS BETWEEN COOKTOP, 
WALLS AND ABOVE THE COOKTOP:
A. Make sure the wall covering, countertop, flooring 
and cabinets around the range can withstand 
the heat (up to 200°F) generated by the range.
B. Allow 30” minimum clearance between surface 
units and bottom of unprotected wood or metal 
cabinet, or allow a 24” minimum when bottom 
of wood or metal cabinet is protected by no 
less than 1/4” thick flame retardant millboard 
covered with not less than No 28 MSG sheet 
metal, (.015”), .015” thick stainless steel, .024” 
aluminum or .020” copper.
Acceptable electrical 
outlet area. Orient 
electrical receptacle 
so the length is 
parallel to floor.
Use a flush mount 
outlet for double 
oven models.
C. This appliance has been approved for 0” spacing to adjacent surfaces above the cooktop. 
However, a 6” minimum spacing to surfaces less than 15” above the cooktop and adjacent 
cabinet is recommended to reduce exposure to steam, grease splatter and heat.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage 
space above the cooktop should be avoided. If cabinet storage space is to be provided above 
the cooktop, the risk can be reduced by installing a range hood that projects at least 5” beyond 
the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 16”.
3”
30”
Unit will not mount flush 
to counter when heights 
are less than 36”.
A
NOTE C
B
A
C
Both 
Sides
29
7
»
8
”
25
7
»
8
”
36”
45
1
»
8
”
29
7
»
8
”
37
1
»
4
”
36”
37
1
»
4
”
25
7
»
8
”
48
1
»
4
”
29
7
»
8
”
29
7
»
8
”