Specification

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
PP9830SR
GE Profile
Series 30" Downdraft Electric Cooktop
Specification Revised 8/22
Listed by
Underwriters
Laboratories
For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
INSTALLING THE DUCTWORK:
Use galvanized or aluminum duct
in 6" round or 3-1/4" x 10" size, or
combination of both.
PVC duct or locally approved piping
should be used if installing under a
poured concrete slab. Local building
code must be followed in specifying
type and schedule of all duct used.
NOTE: Ductwork must be vented
to outside. Do not vent into a wall,
ceiling, crawlspace, attic or any
concealed space. Always use an
appropriate roof or wall cap with
damper.
Laundry-type wall caps should never
be used. For maximum efficiency
use the shortest and straightest duct
run possible, with as few fittings as
possible.
For satisfactory performance the
duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various
duct configurations.
REAR WALL VENTINGDOWNWARD VENTING