PI-450/950 PIR Camera
© 2003 Kalatel, a GE Interlogix company All Rights Reserved. Any GE Interlogix, Kalatel division, software supplied with GE Interlogix, Kalatel division, products is proprietary and furnished under license and can be used or copied only in accordance with the terms of such license. This document contains proprietary information that is protected by copyright.
Installation Instructions PI-450/950 PIR Camera BEFORE YOU BEGIN Read these instructions before installing or operating this product. Note: This installation should be made by a qualified service person and should conform to local codes. This manual provides installation and operation information.
PI-450/950 PIR Camera Installation Instructions MOUNTING THE UNIT 1) Remove the cover (see Figure 1). 2) Unplug the cable. 3) Detach the wires by loosening the terminal screws. 4) Remove the mounting bracket by removing the screw and washer (see Figure 2). Figure 1. Removing the cover 4 Figure 2.
Installation Instructions PI-450/950 PIR Camera Note: Mount the camera with a 3/8-inch (1 cm) clearance from the ceiling. For optimal PIR coverage using the standard lens, mount the PIR 7 feet (2 m) above the floor. You may have to compromise to get good PIR and camera coverage. 5) Mark the mounting holes on the mounting surface (see Figure 3). Cable hole for corner mount Cornermounting holes Surface-mounting holes Figure 3.
PI-450/950 PIR Camera Installation Instructions CONNECTIONS See Figure 4. Video Not used Video ground LED enable/disable jumper Not used Tamper switch Not used Tamper Ground Tamper 12 VDC Normally open Incoming cable harness Common Interconnect to camera Normally closed Figure 4. Circuit board connections Note: Connections can be made using the supplied cable harness ( terminal strip ( – ).
Installation Instructions PI-450/950 PIR Camera LED ENABLE/DISABLE JUMPER Enabled Disabled HIGH DENSITY LENS Figure 5 shows the pattern produced when the PIR is mounted flat against the wall at a height of 7 feet (2 m). The pattern will vary when the PIR is angled to get the best camera view. Figure 5.
PI-450/950 PIR Camera Installation Instructions CAMERA VIEWS 3/8 in. 54º vertical 18º 69º horizontal Figure 6. Camera views with a 3.6 mm lens 3/8 in. 36º vertical 18º 48º horizontal Figure 7.
Installation Instructions PI-450/950 PIR Camera PIR SPECIFICATIONS Electrical Voltage 12 VDC Current 14 mA typical 20 mA max Maximum loop rating 16 VDC, 50 mA Alarm output Failsafe contacts-form C N/C N/O Alarm duration 3.2 sec (± 0.5 sec) Cover tamper contacts N/C Environmental Operating temperatures 14 ºF to 122 ºF (-10 ºC to 50 ºC) Humidity 5% to 95% noncondensing RFI immunity >10 V/m from 10 to 1,000 MHz Static immunity 20 kV Lighting immunity 2.4 kV, 1.
PI-450/950 PIR Camera Installation Instructions CAMERA SPECIFICATIONS PI-450 PI-950 Image sensor 1/3-in. interline transfer CCD 1/3-in. interline transfer CCD Lens options 3.6-mm pinhole standard 5-mm pinhole option 3.6-mm pinhole standard 5-mm pinhole option Scanning system 2:1 interlace, EIA 525 lines/ 60 fields option: CCIR 625/50 2:1 interlace, NTSC 525 lines / 60 fields option: PAL 625/50 Sync system Internal Internal Resolution 425 TV lines 380 TV lines Sensitivity 0.3 lux @ f1.