Specification
DIMENSIONS AND INSTALLATION INFORMATION
Dimension and installation information are shown in inches.
PGP9830DR
GE Profile
™
Series 30" Downdraft Gas Cooktop
For answers to your Monogram, GE Café
™
Series, GE Profile
™
Series or GE
Appliances product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
Specification Revised 8/22
INSTALLING THE DUCTWORK:
Use galvanized or aluminum duct
in 6" round or 3-1/4" x 10" size, or
combination of both. PVC duct or
locally approved piping should be
used if installing under a poured
concrete slab. Local building code
must be followed in specifying type
and schedule of all duct used.
NOTE: Ductwork must be vented
to outside. Do not vent into a wall,
ceiling, crawlspace, attic or any
concealed space. Always use an
appropriate roof or wall cap with
damper.
Laundry-type wall caps should
never be used. For maximum
efficiency use the shortest and
straightest duct run possible, with as
few fittings as possible.
For satisfactory performance the
duct run should not exceed 100
feet equivalent length. Refer to the
table of equivalent lengths (shown in
installation instructions) for various
duct configurations.
Rear Wall VentingDownward Venting
Listed by
Underwriters
Laboratories