Installation Guide

CONVERTING TO LP GAS
(OR CONVERTING BACK TO
NATURAL GAS FROM LP)
This range leaves the factory set for use with
natural gas. If you want to convert to LP
gas, the conversion must be performed by a
qualified LP gas installer.
The conversion orifices and instructions can be
found on back of the range.
Keep these instructions and all orifices in case
you want to convert back to natural gas.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the
range and adjacent combustible surfaces. These
dimensions must be met for safe use of your
range.
Allow 30” (76.2 cm) minimum clearance between
burners and bottom of unprotected wood or
metal cabinet, or allow a 24” (61 cm) minimum
when bottom of wood or metal cabinet is
protected by no less than 1/4” (6.4 mm) thick
flame-retardant millboard covered with no less
than No. 28 MSG sheet metal (.015” [.38 mm]
thick), .015” (.38 mm) thick stainless steel, .025”
(0.64 mm) aluminum or .020” (0.5 mm) copper.
Installation of a listed microwave oven or
cooking appliance over the cooktop shall
conform to the installation instructions packed
with that appliance.
For island installation, maintain 2-1/2” minimum
from cutout to back edge of countertop and
3” minimum from cutout to side edges of
countertop.
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
Rear of Range
Orifice Strip
(location
may vary)
CAUTION To prevent drafts
from affecting burner operation, seal
all openings in floor under appliance
and behind appliance wall.
Maximum depth
for cabinets above
countertops
36"
1/4"
18"
Minimum to
cabinets on
either side
of the range
30"
Minimum
24
3
ø
8
2”
Minimum
clearance to
right wall
2”
Minimum
clearance
to left wall
To cabinets
below
cooktop
and at the
range back
0"
13"
Front edge of
the range side
panel forward
from the
cabinet.
36”
44
3
ø
4
41”
24”
1/4”
2” Minimum
distance to walls
above the cooktop
on each side
5”
2”
3”
5
1
ø
2
30”
2”
3”
8”
8”
12”
Recommended area for 120V
outlet on rear wall and area for
through-the-wall connection of
pipe stub and shut-off valve.
Recommended area for
through-the-floor connection
of pipe stub and shut-off valve.
30” Min.
18” Min.
NOTE: Recommended gas
hook-up locations behind range.
Gas fittings and shut-off valve
should NOT protrude more than
2" from the wall to allow the
range to fit against the wall.
13”
Max
14”
36”
8”
8”
24
3
ø
8
24
3
ø
8