Installation Guide
4
 CHECK SURFACE 
BURNERS
Push and turn a knob to the LITE position. A 
clicking sound indicates proper operation of 
the ignition system. When lighting any burner, 
sparks will appear at all burners but gas flows 
from only the one selected. Once air is purged 
from the supply line, burner should light within 
4 seconds. After burner lights, rotate the knob 
out of the LITE position. Try each burner in 
succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal 
burner flames should look like (A) or (B).
Long, bright yellow flames are not normal. 
Normal flames may show signs of an orange 
tint when well heated or signs of flickering 
orange due to particles in the gas or air.
WHEN ALL HOOKUPS ARE 
COMPLETED
Make sure all controls are left in the off 
position. Make sure the flow of combustion and 
ventilation air to the range is unobstructed.
Check that all packing materials and tape 
have been removed. This will include tape on 
metal panel under control knobs (if applicable), 
adhesive tape, wire ties, cardboard and 
protective plastic. Failure to remove these 
materials could result in damage to the 
appliance once the appliance has been turned 
on and surfaces have heated.
6
 INSTALL AND CHECK ANTI-TIP DEVICE
WARNING
 Never completely 
remove the leveling leg as the range will not 
be secured to the anti-tip device properly.
Follow instructions supplied with ANTI-TIP 
bracket.
Anti-Tip Bracket 
Kit Included
INSTALLATION INSTRUCTION
31-2000746 Rev. 0 06-20 GEA
PGB935
7
 LEVEL THE RANGE
WARNING
 Never completely 
remove the leveling leg as the range will not 
be secured to the anti-tip device properly.
A. Plug in the unit.
B. Measure the height of your countertop at the 
rear of the opening (X).
C. Adjust two rear leveling legs so that the rear 
of cooktop is at the same height or higher 
than the counter (Y).
D. Slide unit into place.
E. Install oven shelves in the oven and position 
the range where it will be installed.
F. Check for levelness by placing a spirit 
level on one of the oven shelves. Take two 
readings—with the level placed diagonally 
first in one direction and then the other.
G. Adjust front leveling legs until the range is 
level.
H. Look under the unit and verify that the rear 
leg is fully engaged with the anti-tip device. If 
not, remove the unit and adjust the height of 
the rear leg so that it is properly engaged.
Spirit level
5
 CHECK BAKE AND BROIL BURNERS
■ Set Bake function to 350°F. Burner should 
light in 30 to 60 seconds.
■ Set broil to Broil Hi. Burner should light in 
30 to 60 seconds.
(A) Soft blue flames—
Normal for natural gas
(B) Yellow tips on 
outer cones—
Normal for propane gas
NOTE: Cooktop must be at or above counter.
Cooktop
0” or Greater
Counter
X
Y