Installation Sheet
2
CUTOUT DIMENSIONS
* Min. depth with receptacle outside cabinet 19
1
»2”
  Min. depth with receptacle inside cabinet 22”
Installation Instructions
Models  27” 30”
Height  16
3
»4” 16
3
»4”
Width  25
1
»2” 25
1
»2”
Depth (min.)*  19
1
»2” or 22” 19
1
»2” or 22”
On 27” models, allow 1
1
»4” at the top, 
9
»16” on the sides 
and 1” at the bottom for overlap of the Trim Frame 
over the edges of the cutout.
On 30” models, allow 1
1
»4”at the top, 2
1
»8” on the sides 
and 1”at the bottom for overlap of the Trim Frame 
over the edges of the cutout. 
For ADA Compliance, the microwave must be 
installed no higher than 36
1
»4”.
Depth
Height
1
”overlap 
Width
1
1
»4” overlap 
1” Clearance 
beyond Trim Frame 
(on all sides)
27
” Models: 
9
»16”overlap 
30” Models: 2
1
»8” overlap
3” min.
CAUTION
This trim kit uses air flow from the top, bottom and 
sides of the trim frame. Blocking the air flow can 
cause the microwave to function improperly and 
may cause damage to the microwave.
Allow a 1” clearance beyond the edge of the Trim 
Frame to provide proper air flow.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of 
an electrical short circuit, grounding reduces the risk 
of electric shock by providing an escape wire for 
the electric current. This appliance is equipped with 
a cord having a grounding wire with a grounding 
plug. The plug must be plugged into an outlet that is 
properly installed and grounded.Consult a qualified 
electrician or serviceman if the grounding instructions 
are not completely understood, or if doubt exists as to 
whether the appliance is properly grounded.
Improper use of 
the grounding plug 
can result in a risk of 
electric shock. 
Do not use an 
extension cord. If the 
power supply cord 
is too short, have a 
qualified electrician 
or serviceman install 
an outlet near the 
appliance.
Permanent and Correct 
Installation
3-Prong plug
Grounding pin
3-Prong receptacle
Grounded receptacle box
WARNING
ELECTRICAL REQUIREMENTS
Product rating is 120 volts AC, 60 Hertz, 14.5 amps 
and 1.70 kilowatts. This product must be connected to 
a supply circuit of the proper voltage and frequency.  
Wire size must conform to the requirements of the 
National Electrical Code or the prevailing local code  
for this kilowatt rating. The power supply cord and 
plug should be brought to a separate 15 to 20 ampere 
branch circuit single grounded outlet. The outlet box 
should be located in the cabinet above the oven. The 
outlet box and supply circuit should be installed by 
a qualified electrician and conform to the National 
Electrical Code or the prevailing local code.