Technical Specifications
Masoneilan 35002 Series Camflex
*
II Rotary Control Valves | 9
(C
V
) Versus Travel
Differential Velocity Device (DVD)
Flow Direction: Flow to Open only
Flow Characteristics: Linear
ANSI Class: 150 through 600
Sizes: 1 in. through 12 in. (DN 25-300)
Low Noise
Device
Body
Differential
Velocity
Device
Flow Direction
Note: The differential velocity device is used for aerodynamic noise reduction. It must be used with .6 factor trim flow to open.
Percent of Plug Rotation 10 20 30 40 50 60 70 80 90 100
Valve Size Orifice Dia. Act. Stem Travel
in. DN in. mm in. mm
1 25 0.579 14.7 3.5 89 0.52 1.04 1.88 2.62 3.23 3.76 4.22 4.58 4.84 5.00
1.5 40 0.907 23.0 3.5 89 1.30 2.60 4.69 6.54 8.06 9.41 10.5 11.4 12.1 12.5
2 50 1.159 29.4 3.5 89 1.88 3.75 6.75 9.42 11.6 13.6 15.2 16.5 17.4 18.0
3 80 1.874 47.6 5.75 146 5.00 10.0 18.0 25.1 31.0 36.1 40.5 43.9 46.4 48.0
4 100 2.419 61.4 5.75 146 8.13 16.3 29.3 40.8 50.3 58.7 65.8 71.4 75.4 77.0
6 150 3.629 92.2 7.25 184 18.9 37.7 67.9 94.7 116 136 153 166 175 181
8 200 4.84 123 7.25 184 32.1 64.2 116 161 199 232 260 282 298 308
10 250 6.05 154 7.25 184 50.6 101 182 254 313 366 410 445 470 486
12 300 7.46 189 7.25 184 71.3 143 257 358 441 515 577 626 661 684