Technical Specifications
4 | GE Oil & Gas
Actuator Mounting Guide
Notes:
1. It is recommended that the actuator always be mounted as shown above. For other positions, consult your local sales office.
2. Installation is assumed to be in the horizontal pipeline for orientation of the airset and other accessories unless specified on the order.
3. Action and orientation are field reversible without additional parts.
4. Operating efficiencies may vary depending on valve configuration.
5. The above schematic does not reflect every possible body/actuator orientation, but should serve as an effective guide.
Flow-To-Open
Flow-To-Close
AIR-TO-OPEN
AIR-TO-OPEN
Flow-To-Open
Recommended Flow Direction
Flow-To-Close
AIR-TO-CLOSE
AIR-TO-CLOSE
Recommended Flow Direction
CAMFLEX II VALVES
(Mounted On Horizontal Pipeline)
3
5
-
3
5
. 0
2
Actuator Position in Relation to Valve Body
Numbering System : 1 to 8
F.T.C
Masoneilan
Masoneilan
CAMFLEX II
4
F.T.O
F.T.O
Masoneilan
Masoneilan
CAMFLEX II
6
F.T.C
F.T.O
Masoneilan
Masoneilan
CAMFLEX II
8
F.T.C
F.T.C
F.T.O
Masoneilan
Masoneilan
CAMFLEX II
2
Plug
Position
Plug
Position
Plug
Position
Plug
Position
F.T.O
F.T.CF.T.C
Masoneilan
Masoneilan
CAMFLEX II
7
F.T.O
F.T.CF.T.C
5
Masoneilan
Masoneilan
CAMFLEX II
F.T.C
Masoneilan
Masoneilan
CAMFLEX II
3
F.T.O
F.T.C
F.T.O
1
MasoneilanMasoneilan
CAMFLEX II
Plug
Position
Plug
Position
Plug
Position
Plug
Position
Position de l’actionneur par rapport au corps
Codification : 1 à 8
NOTES
:
2. Standard actuator mounting positions are shaded
:
2. Plug positions are shown in the initial position without air on actuator.
3. The actuator must be always mounted above the pipeline.