MSDS

Material Safety Data Sheet
Version: 1.6
08/24/2009
M90007
Acetoxy Sanitary Sealant
Page 3/8
medical attention if irritation persists.
NOTE TO PHYSICIAN
Treatment is symptomatic and supportive.
5. FIRE-FIGHTING MEASURES
FLASH POINT:
> 93 °C; 199 °F
METHOD:
estimated
IGNITION TEMPERATURE:
Unknown
FLAMMABLE LIMITS IN AIR - LOWER (%):
not applicable
FLAMMABLE LIMITS IN AIR - UPPER (%):
not applicable
SENSITIVITY TO MECHANICAL IMPACT:
No
SENSITIVITY TO STATIC DISCHARGE
Sensitivity to static discharge is not expected.
EXTINGUISHING MEDIA
All standard extinguishing agents are suitable.
SPECIAL FIRE FIGHTING PROCEDURES
Firefighters must wear NIOSH/MSHA approved positive pressure self-contained breathing
apparatus with full face mask and full protective clothing.
6. ACCIDENTAL RELEASE MEASURES
ACTION TO BE TAKEN IF MATERIAL IS RELEASED OR SPILLED
Wipe, scrape or soak up in an inert material and put in a container for disposal. Wash walking
surfaces with detergent and water to reduce slipping hazard. Wear proper protective equipment as
specified in the protective equipment section.
7. HANDLING AND STORAGE
PRECAUTIONS TO BE TAKEN IN HANDLING AND STORAGE
Product releases acetic acid during application and curing. Use only in well-ventilated areas. Avoid
contact with skin and eyes. Remove contact lenses before using sealant. Do not handle lenses until
all sealant has been cleaned from the fingertips, nails and cuticles. Residual sealant may remain on
fingers for several days and transfer to lenses and cause severe eye irritation.
STORAGE
Store away from heat, sources of ignition, and incompatibles. Keep out of the reach of children. Keep