Manual

Installation Instructions
[] CONNECT WIRING
Connect house black to hood black wire, house
white to hood white wire and house grotmd tamer
green ground screw. Securel) tighten tile strain
relief clamp onto tile house wiring.
WARNING: IMPROPER CONNECTION OF
AI,UMINUM HOUSE X4]RIN(; TO THESE
COPPER I,EADS CAN RESUI,T IN A SERIOUS
PROBI,EM. USE ONLY CONNECTORS
DESIGNED FOIl JOINING COPPER TO
AI,UMINUM AND FOI,I,OX4 THE
MANUE__CTURER'S RECOMMENDED
PROCEDURE CI,OSEI,Y.
[] REPLACE WIRING COVER
CD
Wiring cover
[] REPLACE FILTER
Make sm'e fan blade turns freely and replace tile
filter. NOTE: On model,IV347, install tile metal
grease filter if ducted or tile charcoal filter if
recirculated.
Metal greasefilter or charcoalfilter
Tile installation is complete. Turn on power at
set\ice panel, and test for proper operation.
TROUBLESHOOTING CHECKLIST
If tile hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
inadequate, check the tollowing:
Knockouts not removed fl'om hood.
Damper blade not opening.
Reduced airflow because tile duct is too small or
tile duct length is too long.
The duct is blocked.
Undersized or restrictixe wall or roof cap.
If tile hood seelllS to II/ake excessixe noise:
Fan mav be hitting tile filter, Tm'n off tile tan and
remove the filter; Bend the filter down slightly in the
center (into a dome shape) to allow tan clearance,
Reinstall and a(!just as needed,
Tile fan does not work but tile lights do:
Switch power off at the service panel and lock the
service disconnecting means to prevent power fl'om
being switched on accidentally: When the service
disconnecting means cannot l')e locked, securely
tasten a prominent warning device, such as a tag,
to tile se_xice panel.
Check the wiring connections. See the CONNECT
WIRING section in these Installation Instructions.
16