Manual

Installation Instructions
[] FOR RECESSED-BOTTOM
CABINETS ONLY
If the cabinets have fl'ont, side or back trim, make
2 wood shims the width of the trim and attach then_
to the cabinet 1)()ttom recess on both sides. See Step
10 for marking locations.
[] CUT HOLES
Cut holes at marked h)cations fin" duct and electrical
wiring. For the vertical duct, cut ()tlt 3/4" extra
toward the front of the cabinet so you can move the
duct fl'eely when installing the hood, It may also ease
installation by cutting the hole 10J½" instead of 10".
[] RUN WIRES
Rim the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on tmtil
installation is complete.
[] SCREW IN PARTWAY
Drixe a re(ranting screw (from the hardware packet)
partwa) into each center of the narrow neck of the
keyhole slots marked on the cabinet bottom.
[] OPTIONAL POWER CORD
KIT JXHC1
[]
An optional Power Cord Connection Vdt, model
JXHCI, is available at extra cost fl'om your GE
supplier fin" installation using a standard S-prong,
gr(mnded wall outlet. Follow the h_stallation
Instructions packed with the kit to connect the
power cord to the range hood.
Cabinet
3-prong
outlet
(if using cord
connection}
1%" dia. clearance hole
for optional power
supply location
NOTE: If using optional Power Cord/4&JXHC1,
feed the power cord through the hole in the top
cabinet while raising the hood. I,oop any excess
length of cord and tie away with a suitable tape
or tie.
FEED IN WIRES
I,ift the hood into position and feed the house
wiring through the wiring knockout.
14