Installation Instructions
[] MARK HOLES
Select the xent option that _our installation will
require and proceed to that section:
A. Outside top exhaust
(Vertical duct-31/4" x 10" Rectangular)
Use the diagran_ or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hoodmountingscrews(4)
133/4'' (30" hood)
16W' (36" hood)
133/4'' (30"hood)
163/4'' (36"hood)
Wood shims (recessed- { Electrical access hole
Center (in cabinet bottom)
bottomcabinetsonly) line
B.Outside top exhaust (Vertical duct-T' Round)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hoodmountingscrews(4)
13¾"(30" hood)
(36" hood)
front
13¾"(30" hood)
Electrical access
Wood shims (recessed- Center hole (incabinetbottom)
bottomcabinetsonly) line
C. Outside rear exhaust
(Horizontal duct-31/4" x 10" Rectangular)
Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots,
Woodshims(recessed-bottomcabinetsonly)
B_abiiet frontal//, lY4,,
133/4"(30" hood)
163A"(36" hood) 16sA" (36" hood)
Electricalaccesshole
Hoodmountingscrews(4) line (inwall)
D. Recirculating (non-vented ductless-
JN327 and RN328, and optional on
JV347 and JV367 models only)
Use the hood as a template and mark the locations
on the cabinet for the electrical wiring and keyhole
scI'ew slots.
Since the hood is to be recirculated (not to be xented
outside), do not cut out any xent oi)enings, in the wall
or cabinet bottom.
13