Manual

Installation Instructions
[] REMOVE DUCT KNOCKOUT
If recirculathag, i_oi>vented ductless (1N327 and RN328,
and optional for.fV347 and,IV367 models only), skip to
Step 10 D mid proceed.
Using a fiat blade screwdi'i\'er, relnove the appropriate
duct knockout fl'oln the top or back of the hood.
3'/4"x 10" Rectangular
vertical discharge.
Remove top rectangular
duct knockout only.
7" Roundvertical
discharge.Removecircular
ductknockoutonly.
3'/4" x 10" Rectangular
horizontal discharge. Remove
rear rectangular duct knockout only.
[]
FOR 3ΒΌ" X 10" RECTANGULAR
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Attach exhaust adaptor/damper ()vet" the appropriate
knockout opening (fin" vertical or hot_izontal,
depending on installation) with two exhaust adaptor
screws. Make sure dalnper pivot is nearest to top/back
edge of hood. ]_elnove tape fl'oln dalnper flap.
Upto 1" side-to-
sideadjustment
Exhaustadaptor/damper
(verticaldischargeposition)
Pivot
(dependingon Top/backedge
installation) Exhaustadaptor/damper
(horizontaldischargeposition)
NOTE: The exhaust adaptor/danq)er can be installed
up to 1 inch oi1 either side of the hood center to
accotntnodate oflLcenter ductwork, 111 extretne off L
center installations, one end of the duct connector may
need to be trilnlned to clear the electrical cable clalnp.
[] FOR 7" ROUND VERTICAL
DUCTED DISCHARGE
INSTALLATIONS ONLY:
Bend up the duct alignment eat_ in preparati(m for
later attachment of the t duct.
12