Manual

Installation Instructions
[] INSTALL LIGHT BULB
NOTE: A light bulb is not shipped with tile hood.
Obtain one localE, Purchase and install a type A15
light bulb with an ordinary screw-base, not more
than 60 watts,
[] FOLLOW ELECTRICAL CODE
Corn p] ere the e] ectri ca] wiri m_g accordi m_g to
Nati(ma] Electrical (_ode amid local codes.
NOTE: This hood midst be [_ermam_eN_tE, ,gr°m_ded-
[] REPLACE FILTER
Make sure tim blade turns freely and replace tile
filter, NOTE: Install the metal grease filter if ducted
or tile charcoal filter if recirculated,
/
Metal grease filter or charcoal filter
Tile installation is complete. Turn on power at
set\ice panel, and test for proper operation.
[] CONNECT WIRING
Connect house black to hood black wire, house
white to hood white wire and house ground trader
green ground screw. Securely tighten tile strain
relief clamp onto the house wiring.
l _jGreen groundscrew
WARNING: IMPROPER CONNECTION OF
AI,UMINUM HOUSE WIRING TO THESE
COPPER I,EADS CAN RESUI,T IN A SERIOUS
PROBI,EM. USE ONI,Y CONNECTORS
DESIGNED FOIl JOINING COPPER TO
AI,UMINUM AND FOI,I,OW THE
MANU FACTURER'S RECOMMENDED
PROCEDURE CI,OSEI,Y.
[] REPLACE WIRING COVER
Wiring cover
TROUBLESHOOTING CHECKLIST
If tile hood seems to be operating at high speed when
tile control is not set on high, or if ventilation seems
inadequate, check tile tollowing:
Knockouts not removed from hood.
Damper blade not opening.
Reduced airflow because tile duct is too small or
tile duct length is too long.
Tile duct is blocked.
Undersized or restrictive wall or roof cap.
If tile hood seelllS to II/ake excessixe noise:
Fan mav be hitting tile filter. Tm'n off tile tim and
remove the filter. Bend the filter down slightly in the
center (into a dome shape) to allow tan clearance.
Reinstall and at!just as needed.
Tile tim does not work but tile lights do:
Switch power off at the service panel and lock the
se_wice disconnecting means to prevent power fl'om
being switched on accidentally. When tile service
disconnecting means cannot be locked, securely
thsten a prominent warning device, such as a tag,
to tile service panel.
Check tile wiring connections. See tile CONNECT
WIRING section in these Installation h]structions.
14