Manual
Installation Instructions
[] MARK HOLES
Select the xent option that _our installation will
require and proceed to that section:
A. Outside top exhaust
(Vertical duct-31/4" x 10" Rectangular)
• Use the diagrmn or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Hoodmountingscrews(4)
133/4"(30" hood)
16W' (36" hood)
133/4'' (30"hood)
163/4'' (36"hood)
Wood shims {
recessed-bottomcabinetsCenter
only shimsmustbea ne
minimumof 3/8" thick
andcut to fit tile width
of the innerrecessed
cabinetbottom)
Electricalaccesshole
(incabinetbottom)
B.Outside top exhaust (Vertical duct-T' Round)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wirin<* and kexhole screw slots.
Hoodmountingscrews(4)
133/4"(30" hood) 13¾"(30" hood)
hood) hood)
front
,_/ Cabinet "
bottom
Access _ ] 1W'
;I\ ,e00_0cr o
\ T T
Electricalaccess
hole0ocabinetbottom)
Wood shims
(recessed-bottomcabinets Center
only shimsracistbe amloimtlm line
of 3/8" thickand cut to fit the
width of the inner recessed
cabinet bottom)
C. Outside rear exhaust
(Horizontal duct-31A" x 10" Rectangular)
• Use the diagram or the hood as a template and
mark the locations on the cabinet for ductwork,
electrical wiring and keyhole screw slots.
Wood shims
(recessed-bottomcabinetsonly shimsmustbea
minimumof 3/0" thick andcut to fit the width
of the inner recessedcabinet bottme)
[[__Q Cabinetfront I/zU 11J- I II
• __I accessil,e I l
Cabinet , I "
Ibottom I_-574" _ -<--5V4" _4 ]
_--133/4" (30" hood) ---_ _-137A'_4;;30" hood_ )
163/g' (36" hood) 163/g' (36" hood)
Electricalaccesshole
Hoodmountingscrews(4) (inwall)
D. Reekeulating (non-vented ductiess-
JN327 and RN328, and optional on
JV347, JV348 and JV367 models only)
o [Ise the hood as a template m_d mark the ]ocadol_s
om_ the cabim_et %r the electrical *_ir]m_g amid keyhole
scre_ s] O[S.
o Sim_ce the hood is to be rech'cu]ated (m)t to be ve]_ted
outside), do m_ot cut <rot am_*,veN_t o[>emm_gs<, im_ the wall
o1" cabil/et botto]'_/.
[] CUT HOLES
Cut holes at marked locations for duct and electrical
wiring. For the vertical duct, ('tit Otlt 3/4" extra
toward the fl'ont of the cabinet so you can move the
duct fl'eely when installing the hood. It may also ease
installation by cutting the hole 10½" instead of 10".
[] RUN WIRES
Rtm the electrical wires through the wall or
cabinet according to National Electrical Code
and applicable local codes.
NOTE: DO NOT turn the power on until
installation is complete.
12