LP Conversion JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60, RGBS330 and XGBS400
BURNER OUTPUT RATINGS: BTU/HR
Propane (LP) Gas 10” W.C.P.
BURNER
BTU 
RATE
ORIFICE 
SIZE (mm) COLOR MARKING
RF 12,000 0.039” (0.99) Blue/Magenta 99L
LF 9,500 0.035” (0.89) Blue/Brown 89L
RR 5,000 0.026” (0.66) Red/Yellow 66L
LR 9,500 0.035” (0.89) Blue/Brown 89L
OVEN 16,000 0.048” (1.21) Pink 0.048
To adjust your range for use with propane (LP) gas, follow 
these instructions:
1. Disconnect all electrical power, at the main circuit breaker or 
fuse box.
2. Shut o the gas supply to the range by closing the manual 
shut-o valve.
CONVERTING THE PRESSURE REGULATOR
CONVERTING THE COOKTOP BURNERS
A.  Remove the top grates, burner caps and burner heads. 
B.  Using a 7 mm or 9/32” nut driver, remove the top burner 
orices. These may be accessed through the burner 
opening in the base.
C. Remove the propane (LP) orices from the box provided. 
The propane (LP) orices have the letter “L” on the top.
   To aid in identifying the proper location for the propane (LP) 
orices during conversion from Natural Gas to Propane 
(LP) Gas, color codes have been added to the side or top of 
the orice. See the chart below. Each orice may also show 
a series of engraved marks (I, II, III . . .) located on the top.
The pressure regulator is located on the rear of the range. 
(Some models will have a metal shield protecting the regulator 
that must be removed for conversion and reinstalled when 
conversion is complete.) The pressure regulator is located in the 
lower, left hand side of the range as viewed from the front left.
1.   Use an adjustable wrench to unscrew the hex-nut cap from 
the pressure regulator.
2.   Completely remove the protective plastic cap o the 
threaded metal cap.
3.   Turn the metal cap so the type of gas being converted to is 
displayed and replace the protective plastic cover.
4.   Screw the hex-nut cap back into the regulator. 
(Do not over tighten)
TOOLS REQUIRED:
•  Adjustable wrench
•  1/2” Open-end wrench
•  Phillips head screwdriver
•  Flat bladed screwdriver 
(blade approximately 
3/32” across)
•  Nut drivers: 1/4”, 9/32” 
or 7mm
Pressure Regulator Gas Valve
PROPANE (LP) CONVERSION INSTRUCTIONS
PROPANE
NAT
Rotate cap counter-
clockwise to loosen
Cap assembly
WARNING
   Explosion Hazard
Death or serious injury can result from failure to follow 
these instructions.
• Service by a qualified service technician only.
• Shut off gas supply and disconnect power before servicing.
• Reconnect all grounding devices after service.
• Replace all parts and panels before operating.
NOTICE:
If you are using propane (LP) (bottled) gas, all 
adjustments described in the following steps must be 
made before you make any burner adjustments.
NOTICE:
Save these orices for future conversion back to natural gas.
WARNING
 Do not operate the cooktop or oven 
burners of this range when using propane (LP) (bottled) gas 
before converting the pressure regulator and burner orices 
for propane (LP) gas use. Failure to do so could cause high 
ames and toxic fumes which can result in serious injury.
The pressure regulator and the burner orices are set for 
natural gas. To use propane (LP) gas, the regulator and burner 
orices must be converted. 
D. Install the propane (LP) orices in their precise locations.
To prevent leakage, make sure the orice spuds are securely 
screwed into the gas supply tubes.
E. Install the old orice spuds into the metal box or bracket 
along with these instructions, and replace onto the back of the 
range for possible future conversion.
95
III
Denotes 0.95mm Orifice size opening
Denotes LP (Propane)
Burner 
cap
Burner construction
Burner 
head
Base
Orifice 
located 
through this 
opening
LR
RR
LF RF
Blue/Magenta
Propane
Blue/Brown
Propane
Blue/Brown
Propane
Red/Yellow
Propane
PROPANE (LP) CONVERSION INSTRUCTIONS
31-2000947 Rev. 0 07-21 GEA
JGBS10, JGBS30, JGBS61, RGBS300, RGBS400, JGBS60, RGBS330 and XGBS400
The propane orices for the cooktop burners are shipped on 
the back of the range in the location shown.
Propane Conversion Kit