Installation Guide
CAUTION
 To prevent 
drafts from affecting burner 
operation, seal all openings 
in floor under appliance and 
behind appliance wall.
18”
Minimum 
to cabinets 
above counter
0”
Minimum
to cabinets 
below 
cooktop
30”
Minimum 
30”
15”
Max to 
cabinets 
above 
counter 
3” Right side
6” Left side
Minimum 
to side wall
36”
30”
2”
5”
4”
9”
13”
14 1/2”
24”
4 1/2”
12 1/2”
Side Wall
Gas
and 
electrical
supply
DIMENSIONS AND CLEARANCES
Provide adequate clearances 
between the range and adjacent 
combustible surfaces. These 
dimensions must be met for safe 
use of your range. 
Allow 30” (76.2 cm) minimum 
clearance between burners and 
bottom of unprotected wood or 
metal cabinet, or allow a 24” (61 
cm) minimum when bottom of wood 
or metal cabinet is protected by 
no less than 1/4” (6.4 mm) thick 
flame-retardant millboard covered 
with no less than No. 28 MSG sheet 
metal (.015” [.38 mm] thick), .015” 
(.38 mm) thick stainless steel, .025” 
(0.64 mm) aluminum or .020” (0.5 
mm) copper.
Installation of a listed microwave 
oven or cooking appliance over 
the cooktop shall conform to the 
installation instructions packed with 
that appliance.
For island installation, maintain 
2-1/2” minimum from cutout to 
back edge of countertop and 3” 
minimum from cutout to side edges 
of countertop.
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
CONVERTING TO PROPANE 
GAS (OR CONVERTING 
BACK TO NATURAL GAS 
FROM PROPANE)
This range leaves the factory set for use with 
natural gas. If you want to convert to propane 
gas, the conversion must be performed by a 
qualified propane gas installer.
The conversion orifices and instructions can 
be found on back of the range.
Keep these instructions and all orifices in case 
you want to convert back to natural gas.
INSTALLATION AT HIGH ALTITUDE
Over 6000ft, product configured for natural gas or propane requires installation of kit 
(WB28X29254 for natural gas and WB28X29255 for propane gas). Follow the instructions 
included with the kit.
Rear of Range
Orifice Box 
(location 
may vary) 
Minimum to
cabinets on
either side
of the range.
Minimum
clearance
to left wall
Minimum
Minimum
clearance to
right wall
Maximum
depth for
cabinets above
countertops
Front edge of
the range side
panel forward
from cabinet
To cabinets below cooktop
and at the range back
To cabinets
below
cooktop and
at the range
back
18"
3"
30"
30"
13"
6"
36"
0"
0"
1/4"
GAS PIPE AND ELECTRICAL
OUTLET LOCATIONS
SINGLE OVEN GAS RANGE
Recommended area for 120V
outlet on rear wall and area for
through-the-wall conection of
pipe stub and shut-off valve.
Recommended area
for through-the-floor
connection of pipe stub
and shut-off valve.
4 1/2"
4"
2"
8"
5"
3"
14 1/2"
9"
30"
46 1/4"
28 3/4"
w/ handle
26 1/4"
w/o handle
30"
36 1/4" ± 1/4"
11 1/4"
AB DEFGHC
30" 10 1/4" 46 1-4" 36 1/4" 28 3/4" 3" 6"26 1/4"








