LP Conversion Kit
/RZVHWWLQJDGMXVWPHQWVPXVWEHPDGHZLWKRWKHUEXUQHUVLQ
RSHUDWLRQRQDPHGLXPVHWWLQJ7KLVSURFHGXUHSUHYHQWVWKH
ORZÀDPHIURPEHLQJVHWWRRORZUHVXOWLQJLQWKHÀDPHEHLQJ
H[WLQJXLVKHGZKHQRWKHUEXUQHUVDUHWXUQHGRQ
$7XUQRQDOOVXUIDFHEXUQHUV
%7XUQWKHNQRERQWKHEXUQHUEHLQJDGMXVWHGWR´/2µ
&5HPRYHWKHNQREDQGLQVHUWDVPDOOÀDWEODGHVFUHZGULYHULQWR
WKHYDOYHVKDIWDVVKRZQDQGWXUQFORFNZLVHWRIXOO\WLJKWHQ
GRZQWKHE\SDVVVFUHZ5HSHDWIRUDOOYDOYHV
',IÀDPHDSSHDUVWRRORZRUXQVWDEOHVORZO\WXUQE\SDVVVFUHZ
FRXQWHUFORFNZLVHXQWLODVWDEOHÀDPHH[LVWVIRUHDFKEXUQHU
5HPHPEHURWKHUEXUQHUVPXVWEHWXUQHGRQWRPHGLXP
($GGLWLRQDOO\IRUHDFKEXUQHUEHLQJDGMXVWHGTXLFNO\RSHQ
DQGFORVHWKHRYHQGRRUZKLOHREVHUYLQJÀDPH,IÀDPHLV
H[WLQJXLVKHGFRQWLQXHDGMXVWLQJE\SDVVVFUHZIRUDODUJHU
ÀDPH5HSHDWGRRURSHQLQJVXQWLOÀDPHLVVWDEOH
)5HSODFHWKHNQRE
PROPANE CONVERSION INSTRUCTIONS
31-11027-1 01-16 GE
JGB645
ADDITIONAL INFORMATION
198
III
Denotes 1.98 mm Orifice size opening
Denotes Natural Gas
N
ADJUSTING LOW FLAME SETTING
ON COOKTOP BURNERS
ADJUSTING AIR SHUTTER SETTINGS FOR
BAKE AND BROIL BURNERS
NOTICE:
2QFHWKHFRQYHUVLRQLVFRPSOHWHDQGFRQ¿UPHG
¿OORXWWKHSURSDQHVWLFNHUDQGLQFOXGH\RXUQDPH
RUJDQL]DWLRQDQGGDWHFRQYHUVLRQZDVPDGH$SSO\WKH
VWLFNHUWRWKHUDQJHQHDUWKHUHJXODWRUWRDOHUWRWKHUV
LQWKHIXWXUHWKDWWKLVDSSOLDQFHKDVEHHQFRQYHUWHG
WRSURSDQH,IFRQYHUWLQJEDFNWRQDWXUDOJDVIURP
SURSDQHSOHDVHUHPRYHWKHVWLFNHUVRRWKHUVNQRZWKH
DSSOLDQFHLVVHWWRXVHQDWXUDOJDV
1. Turn on the gas.
7XUQRQWKHHOHFWULFLW\
5HSODFHWKHRYHQERWWRPDQG
UHLQVWDOOWKHRYHQGRRU
7XUQRQWKHEDNHEXUQHU
$V\RXZDWFKWKHÀDPHZLWKWKH
RYHQGRRUFORVHGFKHFNWKHIROORZLQJ
WKURXJKWKHRYHQGRRUZLQGRZ
D ,IWKHÀDPHVDUH\HOORZRSHQWKHDLUVKXWWHUPRUH8VHD
VFUHZGULYHUWRORRVHQWKHDLUVKXWWHUVFUHZ
E ,IWKHÀDPHVEORZDZD\RUÀXWWHUIURPWKHEXUQHUFORVHWKH
DLUVKXWWHUVOLJKWO\
5HWLJKWHQWKHDLUVKXWWHUVFUHZ
5HSHDWVWHSVWKURXJKIRUWKHEURLOEXUQHU
2YHQEXUQHUÀDPHPXVWEHREVHUYHGZLWKWKHGRRUFORVHGWR
SURSHUO\FKHFNÀDPHFKDUDFWHULVWLFV
&KHFNLQJWKHÀDPHVL]H
,WVKRXOGEHDSSUR[LPDWHO\
µWRµORQJIRUWKHEDNH
and broil burners.
7KHFRPEXVWLRQTXDOLW\RIWKH
EXUQHUÀDPHVQHHGVWREH
GHWHUPLQHGYLVXDOO\
127(,IEXUQHUÀDPHVORRN
OLNH$IXUWKHUDLUVKXWWHUDGMXVWPHQWLVUHTXLUHG1RUPDO
EXUQHUÀDPHVVKRXOGORRNOLNH%RU&GHSHQGLQJRQWKH
W\SHRIJDV\RXXVH:LWKSURSDQHJDVVRPH\HOORZWLSSLQJ
RQWKHRXWHUFRQHVLVQRUPDO
)RUHLJQSDUWLFOHVLQWKHJDVOLQHPD\FDXVHDQRUDQJHÀDPHDW
¿UVWEXWWKLVZLOOVRRQGLVDSSHDU
:KHQDOODGMXVWPHQWVDUHPDGHDQGWKHUHVXOWVDUH
VDWLVIDFWRU\
D 5HSODFHWKHRYHQERWWRP
E 5HSODFHWKHVWRUDJHGUDZHU
SPECIAL NOTE:
To convert the oven back to natural gas, reverse the
LQVWUXFWLRQVJLYHQLQPDNLQJSURSDQHDGMXVWPHQWV
6FUHZ
Air shutter
(A) Yellow flames:
Further Adjustment
Required
(B) Yellow tips on
outer cones:
Normal for Propane Gas
(C) Soft blue flames:
Normal for Natural Gas
WARNING
,I\RXDWWHPSWWRPHDVXUHWKHLQQHUFRQHRIWKHÀDPHSOHDVHXVH
FDXWLRQEXUQVFRXOGUHVXOW
&HQWHUDGMXVWPHQWVFUHZIRUDOOEXUQHUV
BURNER OUTPUT RATINGS: BTU/HR
1*1DWXUDO*DVµ:&3
BURNER
BTU
RATE
ORIFICE SIZE
(mm)
COLOR MARKINGS
RF µ *UHHQ 1
/) µ Brown 1
RR µ Red 1
/5 µ :KLWH3XUSOH 1
%$.( µ 1RQH
%52,/ µ Red 1