Quick Specs
GUD24ESSM/24GSSM
GE
®
Unitized Spacemaker
®
2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer
For answers to your Monogram, GE Café
™
Series, GE Profile
™
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Specification Revised 2/20
Listed by
Underwriters
Laboratories
For complete information, see installation instructions packed with your dryer.
DUCTING MATERIALS: For best performance, this dryer should be vented
with 4" diameter all rigid metal exhaust duct. If rigid metal duct cannot be
used, then UL-listed flexible metal (semi-rigid) ducting can be used (Kit
WX08X10077). In special installations, it may be necessary to connect the dryer
to the house vent using a flexible metal (foil-type) duct. A UL-listed flexible
metal (foil-type) duct may be used ONLY in installations where rigid metal or
flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter
can be maintained throughout the entire length of the transition duct. Please
see installation instruction packed with your dryer for complete instructions
when using flexible metal (foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you
exhaust to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be
tolerated is shown in the table.
For every extra 90° elbow, reduce the allowable vent system length by 10 ft. Two
45° elbows will be treated like one 90° elbow. For the side exhaust installations,
add one 90° elbow to the chart. The total vent system length includes all the
straight portions and elbows of the system (transition duct included).
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under
any enclosed house floor (crawl space), or into an attic, since the accumulated
lint could create a fire hazard or moisture could cause damage. Never terminate
the exhaust into a common duct or plenum with a kitchen exhaust, since the
combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back
drafts, bird nesting, etc. The wall cap must also be located at least 12" above the
ground or any other obstruction with the opening pointed down.
GUD24 DRYER EXHAUST LENGTH*
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
43 Feet
33 Feet
24 Feet
0
1
2
36 Feet
26 Feet
16 Feet
Use only
for short
run installations