Quick Specification

GUD24ESSM/24GSSM
GE
®
Unitized Spacemaker
®
2.3 DOE Cu. Ft. Stainless Steel Washer and 4.4 Cu. Ft. Dryer
For answers to your Monogram, GE Café
, GE Profile
or GE Appliances
product questions, visit our website at geappliances.com or call
GE Answer Center
®
Service, 800.626.2000.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Specification Revised 1/21
Listed by
Underwriters
Laboratories
Special Installation Requirements
ALCOVE OR CLOSET INSTALLATION:
If your dryer is approved for installation in an alcove or closet, it will
be stated on a label on the dryer back.
– The dryer MUST be exhausted to the outside.
Minimum clearances between dryer cabinet and adjacent walls or
other surfaces are: 0" both sides and rear, 1" front and top
Minimum vertical space from floor to overhead cabinets, ceilings, etc.
is 75-1/2".
Closet doors must be louvered or otherwise ventilated and must
contain a minimum of 60 sq. in. of open area equally distributed. If
this closet contains both a washer and a dryer, doors must contain a
minimum of 120 sq. in. of open area equally distributed.
No other fuel-burning appliance shall be installed in the same close
with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
– The dryer MUST be exhausted to the outdoors.
The installation must conform with the local codes, or in the absence
of local codes, with the National Electric Code and National Fuel Gas
Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET
INSTALLATION:
Minimum clearances to combustible surfaces:
0" both sides and rear
1" front and top
GUD24 DRYER EXHAUST LENGTH*
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elbows
Rigid
Metal
Rigid
Metal
43 Feet
33 Feet
24 Feet
0
1
2
36 Feet
26 Feet
16 Feet
Use only
for short
run installations