Installation guide

Installation instructions
CONNECTING APPLIANCE USING 4-WIRE
CONNECTION (MUST BE USED FOR
MOBILE HOME INSTALLATION} (Cont.}
6. Connect power cord as follows:
A. Connect the 2 hot lines to the outer screws of the
terminal block (marked L! and L2).
B.Connect the neutral (white) line to the center of the
terminal block (marked N).
7. Attach ground wire of power cord with the green ground
screw (hole above strain relief bracket). Tighten all
terminal block screws (:3)securely.
8. Properly secure power cord to strain relief.
9. Reinstall the cover.
JLWf_KI_Iil_I_: NEVER LEAVE THE
COVER OFF OF THE TERMINAL BLOCK.
EXHAUST INFORMATION
WARNING - IN CANADAANDIN
THE UNITED STATES, THE REQUIRED EXHAUST
DUCT DIAMETER IS 4 IN (102ram). DO NOT
USE DUCT LONGER THAN SPECIFIED IN THE
EXHAUST LENGTH TABLE.
Using exhaust longer than specified length will:
, Increase the drying times and the energy cost.
, Reduce the dryer life.
, Accumulate lint, creating a potential fire hazard.
The correct exhaust installation is YOURRESPONSIBILITY.
Problems due to incorrect installation are not covered by
the warranty.
Remove and discard existing plastic or metal foil transition
duct and replace with ULlisted transition duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of
duct, number of turns, the type of exhaust hood (wall cap),
and all conditions noted below. The maximum duct length
for rigid metal duct is shown in the following table.
27" DRYER EXHAUST LENGTH
RECOMMENDEDMAXIMUMLENGTH
Exhaust Hood Types
Recommended
Use only for short
run installations
_'1DIA
.......
Rigid
Metal
56 Feet
48 Feet
40 Feet
32 Feet
No, of 90 ° Rigid
Elbows Metal
0 42 Feet
1 34 Feet
2 26 Feet
3 18 Feet
EXHAUST INFORMATION (cont.}
24" DRYER EXHAUST LENGTH
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Tgpes
Recommended
Use onlg for short
run installations
4" DIA
_'d I_ 2 1/2"
No. of 90 ° Rigid
Elbows Metal
0 /43 Feet 36 Feet
i 33 Feet 26 Feet
2 24 Feet 16 Feet
, For every additional 90° elbow, reduce the allowable vent
system length by 10ft.
, Two 45° elbows will betreated likeone 90° elbow. Forthe side
exhaust installations, add one 90° elbow to the chart.
, The total vent system length includes allthe straight portions
and elbows of the system (transition duct included).
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
, Terminate in a manner to prevent back drafts or entry of
birds or other wildlife.
, Termination should present minimal resistance to
the exhaust air fiow and should require little or no
maintenance to prevent clogging.
,Never install a screen in or over the exhaust duct. This
could cause lint build up.
, Wall caps must be installed at least 12 in. above ground
level or any other obstruction with the opening pointed
down.
SEPARATIONOF TURNS
For best performance, separate all turns by at least 4 ft.
of straight duct, including distance between last turn and
exhaust hood.
TURNSOTHERTHAN 90°
* One turn of 45oor less may be ignored.
* Two 45oturns should be treated as one 90oturn.
* Each turn over 45oshould be treated as one 90oturn.
SEALING OFJOINTS
. All joints should be tight to avoid leaks. The male end of
each section of duct must point away from the dryer.
* Do not assemble the ductwork with fasteners that extend
into the duct. They will serve as a collection point for lint.
, Duct joints can be made air and moisture-tight by
wrapping the overlapped joints with duct tape.
, Horizontal runs should slope down toward the outdoors
1/4 inch per foot
INSULATION
Duct work that runs through an unheated area or is near air
conditioning should be insulated to reduce condensation
and lint build-up.