DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all-rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal
(semi-rigid) ducting can be used (Kit WX08X10077). In special installations, it
may be necessary to connect the dryer to the house vent using a flexible metal
(foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used ONLY in
installations where rigid metal or flexible metal (semi-rigid) ducting cannot be
used AND where a 4" diameter can be maintained throughout the entire length
of the transition duct. Please see installation instruction packed with your dryer
for complete instructions when using flexible metal (foil-type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust
to the side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be
tolerated is shown in the table. A turn of 45° or less may be ignored. Two 45°
turns within the duct length should be treated as a 90° elbow. A turn over 45°
should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety, do not terminate exhaust into a chimney, under
any enclosed house floor (crawl space), or into an attic, since the accumulated
lint could create a fire hazard or moisture could cause damage. Never terminate
the exhaust into a common duct or plenum with a kitchen exhaust, since the
combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back
drafts, bird nesting, etc. The wall cap must also be located at least 12" above
the ground or any other obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
DRYER EXHAUSTING INFORMATION
USE METAL DUCT ONLY VERTICAL AND
HORIZONTAL DUCTING
A
B
2-1/2
4
GE Dryer Vent
A
B
2-1/2
4
GE Dryer Vent
A
BEST PERFORMANCE
Maximum length
of 4" dia rigid
metal duct
Exhaust hood type
Domestic dryer models
Number
of 90°
turns
A
4"
opening
B
2-1/2"
opening
Long Vent 6.1-7.4 cu. ft.
capacity electric & gas
(GTD33, GTD42, GTD45,
GTD48, GTD65, GTX22,
GTX33, GTX42 and GTX65)
0 120 ft. 90 ft.
1 100 ft. 75 ft.
2 85 ft. 65 ft.
3 70 ft. 55 ft.
4 60 ft. 45 ft.
5 55 ft. 35 ft.
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow
.
For the side exhaust installations, add one 90° elbow to the chart.
When calculating the total vent system length, you must add all
the straight portions and elbows of the system (including the
transition duct.)
Specification Revised 02/24
*Order online at GEApplianceparts.com, 24 hours a day or by phone at 877.959.8688 during normal business hours.
For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions, visit our website
at geappliances.com or call GE Answer Center® Service, 800.626.2000.
Listed by
Underwriters
Laboratories
*Note that this is a contract exclusive model