Specification
Listed by
Underwriters
Laboratories
GTD48EASWWB
GE® 7.2 cu. ft. Capacity Electric Dryer with up to 120 ft. Venting and Extended Tumble
22 1/2"
"
26"
3 1/2
8
29 1/2
"
37 1/2"
44"
27"
5"
Power Cord 4 1/2
11 3/4"
Side View
Rear View
SIDE VIEW REAR VIEW
ELECTRIC DRYER RATING:
240V 5600W 24A 60Hz
208V 4400W 22A 60Hz
EXHAUST OPTION: 4-way rear, right, left and bottom.
CIRCUIT REQUIREMENTS: An individual, properly-grounded branch circuit,
protected by a 30-amp circuit breaker or a time-delay fuse, is required.
NOTE: Dryer wall outlet must be located within 36" of service cord entry
and accessible when dryer is mounted in position.
INSTALLATION INFORMATION: For complete information, see installation
instructions packed with your dryer.
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION:
- If your dryer is approved for installation in an alcove or closet, it will be stated
on a label on the dryer back.
- The dryer MUST be exhausted to the outside.
- Minimum clearances between dryer cabinet and adjacent walls or other surfaces
are: 0" either side; 1" front, top and rear.
- Closet doors must be louvered or otherwise ventilated and must contain a minimum
of 60 sq. in. of open area equally distributed. If this closet contains both a washer
and a dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
- No other fuel-burning appliance shall be installed in the same closet with a gas dryer.
BATHROOM OR BEDROOM INSTALLATION:
- The dryer MUST be exhausted to the outdoors.
- The installation must conform with the local codes, or in the absence of local codes,
with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATION:
- Minimum clearances to combustible surfaces are: 0" both sides; 1" rear.
DRYER EXHAUSTING INFORMATION: Use metal duct only, vertical and horizontal ducting.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
Part Number
WX9X2
WX9X3
WX9X4
WX9X18
WX9X19
WX9X20
Type
3-Prong
3-Prong
3-Prong
4-Prong
4-Prong
4-Prong
Length
4 Feet
5 Feet
6 Feet
4 Feet
5 Feet
6 Feet
Amperage
30
30
30
30
30
30
POWER CORDS:
GE Appliances strongly recommends the use of factory specified
parts. Select the power cord to fit your installaton requirements.*
NOTE: If the dryer circuit is on a circuit protected by a GFCI breaker,
then 3-wire installation is not permitted. Hose wiring and dryer must
be configured for 4-wire.
For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions,
visit our website at geappliances.com or call GE Answer Center® Service, 800.626.2000.
*Note that this is a contract exclusive model
Specification Revised 02/24