Specification
GTD38EASWWS
GE® 7.2 cu. ft. Capacity Electric Dryer with up to 120 ft. Venting and Reversible Door
DRYER EXHAUSTING INFORMATION—
USE METAL DUCT ONLY VERTICAL AND
HORIZONTAL DUCTING
A
4
B
2-1/2
BEST PERFORMANCE
Maximum length
of 4" dia rigid
metal duct
Exhaust hood type
Domestic dryer models
Number
of 90°
turns
A
4"
opening
B
2-1/2"
opening
Long Vent 6.1-7.4 cu. ft.
capacity electric & gas
(GTD33, GTD38, GTD42,
GTD45, GTD65, GTX22,
GTX33, GTX42 and GTX65)
0 120 ft. 90 ft.
1 100 ft. 75 ft.
2 85 ft. 65 ft.
3 70 ft. 55 ft.
4 60 ft. 45 ft.
5 55 ft. 35 ft.
For every extra 90° elbow, reduce the allowable vent system
length by 10 ft.
Two 45° elbows will be treated like one 90° elbow.
F
or the side exhaust installations, add one 90° elbow to the chart.
When calculating the total vent system length, you must add all
the straight portions and elbows of the system (including the
transition duct) .
FOR COMPLETE INFORMATION, SEE INSTALLATION INSTRUCTIONS PACKED
WITH YOUR DRYER.
DUCTING MATERIALS:
For best performance, this dryer should be vented with 4" diameter all-rigid metal
exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid)
ducting can be used (Kit WX08X10077). In special installations, it may be necessary to
connect the dryer to the house vent using a flexible metal (foil-type) duct. A UL-listed
flexible metal (foil-type) duct may be used ONLY in installations where rigid metal or
flexible metal (semi-rigid) ducting cannot be used AND where a 4" diameter can be
maintained throughout the entire length of the transition duct. Please see installation
instruction packed with your dryer for complete instructions when using flexible metal
(foil-type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4" rigid (aluminum or galvanized) duct which can be tolerat-
ed is shown in the table. A turn of 45° or less may be ignored. Two 45° turns within
the duct length should be treated as a 90° elbow. A turn over 45° should be treated
as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety, do not terminate exhaust into a chimney, under any
enclosed house floor (crawl space), or into an attic, since the accumulated lint could
create a fire hazard or moisture could cause damage. Never terminate the exhaust into a
common duct or plenum with a kitchen exhaust, since the combination of lint and grease
could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird
nesting, etc. The wall cap must also be located at least 12" above the ground or any other
obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES, PLEASE CALL
1-800-GE-CARES.
Specification Revised 02/24
Part Number
WX9X2
WX9X3
WX9X4
WX9X18
WX9X19
WX9X20
Type
3-Prong
3-Prong
3-Prong
4-Prong
4-Prong
4-Prong
Length
4 Feet
5 Feet
6 Feet
4 Feet
5 Feet
6 Feet
Amperage
30
30
30
30
30
30
POWER CORDS:
GE Appliances strongly recommends the use of factory specified
parts. Select the power cord to fit your installaton requirements.*
NOTE: If the dryer circuit is on a circuit protected by a GFCI breaker,
then 3-wire installation is not permitted. Hose wiring and dryer must
be configured for 4-wire.
*Order online at GEApplianceparts.com, 24 hours a day or by phone at 877.959.8688 during normal business hours.
For answers to your Monogram, Café™, GE Profile™ or GE Appliances product questions, visit our website
at geappliances.com or call GE Answer Center® Service, 800.626.2000.