3HUIRUPDQFH'DWD6KHHW
SmartWater
)LOWUDWLRQ6\VWHP²*($SSOLDQFHV0:)&DUWULGJH 
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the 
SHUPLVVLEOHOLPLWIRUZDWHUOHDYLQJWKHV\VWHPDVVSHFLILHGLQ16)$16,6WDQGDUGDQG6WDQGDUG6\VWHPWHVWHGDQGFHUWLILHGE\16)
,QWHUQDWLRQDODJDLQVW16)$16,6WDQGDUGDQG6WDQGDUGIRUWKHUHGXFWLRQRIVXEVWDQFHVOLVWHGEHORZ
The following pharmaceutical reduction claims have not been certified by NSF International or the state of California. 
Claims tested and verified by independent laboratory:
Contaminant 
Reduction
Average 
Influent
NSF specified 
 Challenge 
Concentration
Avg % 
Reduction
Average 
Product Water 
Concentration
Max Permissible  
Product Water 
Concentration
NSF Reduction 
Requirements
NSF 
Test Report
Atenolol 978 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121587
Fluoxetine 907 ng/l N/A 99.4% 5.4 ng/L N/A N/A J-00121587
Ibuprofen 885 ng/L N/A 94.1% 52.3 ng/L N/A N/A J-00121588
Progesterone 1097 ng/L N/A 99.5% 5.0 ng/L N/A N/A J-00121589
Trimethoprim 415 ng/L N/A 99.5% 2.0 ng/L N/A N/A J-00121587
,WLVHVVHQWLDOWKDWWKHPDQXIDFWXUHU¶VUHFRPPHQGHGLQVWDOODWLRQPDLQWHQDQFHDQGILOWHUUHSODFHPHQWUHTXLUHPHQWVEHFDUULHGRXWIRUWKHSURGXFWWRSHUIRUPDV
DGYHUWLVHG6HH,QVWDOODWLRQ0DQXDOIRU:DUUDQW\LQIRUPDWLRQ
Application Guidelines/Water Supply Parameters
6HUYLFH)ORZ 0.5 gpm (21.9 lpm)
Water Supply Potable Water
Water Pressure 40-120 psi (276-827 kPa)
Water Temperature ))&&
Capacity 300 Gallons (1,135 Liters).   Contaminant Reduction Determined by NSF testing.
Substance Tested 
for Reduction
Average 
Influent
NSF specified 
 Challenge 
Concentration
Avg % 
Reduction
Average 
Product Water  
Concentration
Max Permissible 
Product Water 
Concentration
NSF Reduction 
Requirements
NSF 
Test Report
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 97.4% 0.05 mg/L N/A  J-00137878
Nominal Particulate Class 
,WRP 11,333,333 pts/mL At least 10,000 particles/mL 99.9% 5,510 pts/mL N/A  J-00137881
Cyst* 101,000 cysts/L Minimum 50,000 cysts/L 99.99% 1 cyst/L N/A  J-00100036
Asbestos 133 MF/L
10
7
 to 10
8
 fibers/L; fibers 
JUHDWHUWKDQPLQOHQJWK >99% 0)/ N/A  J-00137886
Atrazine 0.008 mg/L 0.009 mg/L ± 10% 91.3% 0.0007 mg/L 0.003 mg/L N/A J-00137910
Benzene 0.014 mg/L 0.015 mg/L ± 10%± 96.5% 0.0005 mg/L 0.005 mg/L N/A J-00137912
Carbofuran 0.08 mg/L 0.08 mg/L ± 10% 74.5% 0.01 mg/L 0.04 mg/L N/A J-00147488
Endrin 0.007 mg/L 0.006 mg/L ± 10% 97.1% 0.0002 mg/L  0.002 mg/L N/A J-00100039
Lead @ pH 6.5 0.148 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00137914
Lead @ pH 8.5 0.155 mg/L 0.15 mg/L ± 10% 99.3% 0.001 mg/L 0.010 mg/L N/A J-00137915
Lindane 0.002 mg/L 0.002 mg/L ± 10% 96.5% 0.00002 mg/L 0.0002 mg/L  N/A J-00137924
Mercury @ pH 6.5 0.006 mg/L 0.006 mg/L ± 10% 87.6% 0.0004 mg/L 0.002 mg/L N/A J-00137925
Mercury @ pH 8.5 0.006 mg/L 0.006 mg/L ± 10% 93.2% 0.0007 mg/L 0.07 mg/L N/A J-00092355
P-Dichlorobenzene 0.223 mg/L 0.225 mg/L ± 10% 99.8% 0.005 mg/L 0.075 mg/L N/A J-00137926
Tetrachloroethylene 0.014 mg/L 0.015 mg/L ± 10% 96.5% 0.0005 mg/L 0.005 mg/L N/A J-00137929
Toxaphene 0.017 mg/L 0.015 mg/L ± 10% >93.9% 0.001 mg/L 0.003 mg/L N/A J-00137928
2, 4-D 0.192 mg/L 0.210 mg/L ± 10% 77.7% 0.040 mg/L 0.07 mg/L N/A J-00147489
*Based on the use of Cryptosporidium parvum oocysts.
NOTE: While the testing was performed under standard laboratory 
conditions, actual performance may vary. Contaminant reduction 
testing is conducted every five years by certifying agency to 
maintain certification.
5HSODFHPHQW&DUWULGJH0:))RUHVWLPDWHGFRVWVRIUHSODFHPHQW
elements please call 1.877.959.8688 or visit our website at 
geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
•  Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before and 
after the system. Systems certified for cyst reduction may be 
used on disinfected water that may contain filterable cysts. 
NOTICE
To reduce the risk associated with property damage due to 
water leakage:
• Read and follow use instructions before installation and use of 
this system.
,QVWDOODWLRQDQGXVHMUST comply with all state and local 
plumbing codes.
• Do notLQVWDOOLIZDWHUSUHVVXUHH[FHHGVSVLN3D,I
your water pressure exceeds 80 psi (552 kPa), you must install 
a pressure-limiting valve. Contact a plumbing professional if you 
are uncertain how to check your water pressure. 
• Do notLQVWDOOZKHUHZDWHUKDPPHUFRQGLWLRQVPD\RFFXU,I
water hammer conditions exist you must install a water hammer 
arrester. Contact a plumbing professional if you are uncertain 
how to check for this condition.
• Do not install on hot water supply lines. The maximum operating 
ZDWHUWHPSHUDWXUHRIWKLVILOWHUV\VWHPLV)&
•  Protect filter from freezing. 'UDLQILOWHUZKHQWHPSHUDWXUHVGURS
EHORZ)&
• The disposable filter cartridge should be replaced every 6 
months at the rated capacity, or sooner if a noticeable reduction 
in flow rate occurs.
Tested and certified by NSF International against 
NSF/ANSI Standard 42 and Standard 53 in model 
GE Appliances MWF for the reduction of the 
claims specified on the performance data sheet.
REPLACEMENT 
 ELEMENT