Installation Guide
Table Of Contents
5
 3-WIRE INSTALLATION (cont.)
NOTE: ALUMINUM WIRING: Aluminum 
building wire may be used but it must be rated 
for the correct amperage and voltage. 
D. Replace wire cover on range back and 
replace the screws that were removed 
earlier. Make sure no wires are pinched 
between cover and range back.
PROCEED TO STEP 6.
6
 4-WIRE INSTALLATION
WARNING
 The neutral wire of the supply 
circuit must be connected to the neutral terminal 
located in the lower center of the terminal block. 
The power leads must be connected to the 
lower left and the lower right terminals of the 
terminal block. The grounding lead must be 
connected to the range with the ground plate 
and the green ground screw.
FOR POWER CORD INSTALLATION
A. Remove the 3 lower terminal screws from 
the terminal block. Remove the ground 
screw and ground plate and retain them. 
Remove and discard the ground strap. DO 
NOT DISCARD ANY SCREWS.
B.  Insert the one ground screw into the power 
cord ground wire terminal ring, through the 
ground plate and into the range.
C. Insert the 3 
terminal screws 
(removed earlier) 
through each 
power cord 
terminal ring and 
into the lower 
terminals of the 
terminal block. 
Be certain that 
the center wire 
(white/neutral) is connected to the center 
lower position of the terminal block. Tighten 
screws securely into the terminal block.
6
 4-WIRE INSTALLATION (cont.)
D. Replace wire cover on range back and 
replace the screws that were removed 
earlier. Make sure no wires are pinched 
between cover and range back.
FOR CONDUIT INSTALLATION
A. Loosen the 3 lower terminal screws on the 
terminal block. Strip wire to exposed tip 
about 5/8” long.
B. Insert the center (white/neutral) wire tip 
through the bottom center terminal block 
opening. On certain models, the wire will 
need to be inserted through the ground strap 
opening and then into the bottom center 
block opening. Insert the two side bare wire 
tips into the lower left and the lower right 
terminal block openings. 
C. Tighten the screws until the wire is firmly 
secured (35 to 50 inch-lbs.). Do not over-
tighten the screws.
NOTE: ALUMINUM WIRING: Aluminum 
building wire may be used but it must be rated 
for the correct amperage and voltage. 
Before–Power Cord and Conduit
Terminal 
block
Neutral terminal
Ground 
strap
Ground strap 
Ground plate
Terminal 
block
Ground 
screw
After–Power Cord
Ground 
plate 
(grounding 
to range)
After–Conduit
Terminal 
block
Ground 
plate 
(grounding 
to range)
Wire 
tips
Ground 
screw
7
 ANTI-TIP DEVICE INSTALLATION
To reduce the risk of tipping the range, the 
range must be secured by a properly installed 
anti-tip bracket. Remove any currently used 
anti-tip bracket and install with the provided 
anti-tip bracket. 
1.  IMPORTANT: Determine the final location 
of the range before attempting to install the 
bracket. Remove existing anti-tip bracket 
from install space, if present.
a. Place the bracket on the floor with the 
back edge against the rear wall. If the 
range does not reach the rear wall, align 
the back edge of the bracket with the rear 
panel of the range in its final location.
 If bracket does not touch the rear wall, 
you MUST screw bracket to FLOOR as 
described in Step 2. 
b. Position the side of the bracket against 
either the left or right cabinet. If there is 
no adjacent cabinet, align the edge of 
the bracket with the side panel of the 
range in its final location. If the countertop 
overhangs The cabinet, offset the bracket 
from the cabinet by the amount of 
overhang.
c. Mark the location for the pair of holes to be 
used (see illustration above).
  NOTE: For FLOOR installation use either 
Loc A or B. For REAR WALL installation 
use Loc C.
2. The bracket must be screwed to either the 
FLOOR or REAR WALL.
FLOOR Installation:
WOOD FLOOR: Use the screws provided to 
secure the bracket using the pair of marked 
holes (either Loc A or B).
CONCRETE FLOOR: Using a concrete 
bit, drill a 5/32” pilot hole 2” deep into the 
concrete at the center of each of the marked 
holes (either Loc A or B). Use the screws 
provided to secure the bracket into the floor.
REAR WALL Installation:
Use the 2 screws provided to secure the 
bracket using the pair of marked holes at 
Loc C. The screws MUST enter into a wood 
sill plate. If the wall contains any metal studs 
or similar materials, then the floor must be 
used.
3. To check if the bracket is installed and 
engaged properly, look underneath the 
range to see that the rear leveling leg is 
engaged in the bracket. On some models, 
the storage drawer or kick panel can be 
removed for easy inspection. If visual 
inspection is not possible, slide the range 
forward, confirm the anti-tip bracket is 
securely attached to the floor or wall, and 
slide the range back so the rear leveling 
leg is under the anti-tip bracket. If your 
range is removed for cleaning, servicing, 
or any reason, be sure the anti-tip device 
is reengaged properly when the range is 
replaced. Failure to take this precaution 
could result in tipping of the range and can 
result in death or serious burns to children 
or adults. Never completely remove the 
leveling legs or the range will not be secured 
to the anti-tip device properly. 
Anti-Tip 
Bracket Kit 
Included
Loc A
Loc B
Loc C
Two screws must enter floor 
at Loc A or B or wall at Loc C.
Rear Wall
Screw must enter  
wood or concrete
Attachment to Floor or Rear Wall
Wall Sill Plate
Screw must enter wood
Bracket
•  A child or adult can tip the range and be killed.
•  Install the anti-tip bracket provided with the unit 
 to the wall or floor.
•  Engage the range to the anti-tip bracket by sliding the 
  range back such that the foot is engaged.
•  Re-engage the anti-tip bracket if the range is moved.
•  Failure to do so can result in death or serious burns
  to children or adults.
Tip-Over Hazard
WARNING