Problem Possible Causes What To Do
Water contains tiny New filter cartridges eontahl "['tu'n o_l _1%%ratert_lll(e| _111(t_]]()_%rtl_('S(' II_'_II('SS ( _l]_t)()l_1)artJ(les to
black particles activated carbon, which is })/lrge t_'onl ltle cartridge, Turn oil ltle t_ulcel wtlel) the water is (lear.
a harmless black powder.
Water has air bubbles Air in system after installation. Will go awm a/ler water runs tor a while.
and is cloudy
Indicator light on the Three lnonths usage has occurred. Rel)la(e fiher (aru:i(Ige and 1)atteries in the timer.
timer is flashing This is the maximum life of the Reset timer b_ holding _t()X_rllt]_¢_l'_S¢_t button t_)r 5 seconds.
filter cartridges.
Indicator light on the Timer operating normally. I Jght flashed 5 dines when reset. It will not flash again umil 3 months
timer is not working ha_e t)asse(t.
No a(tion required.
Batteries may need to be ()l)serve orientation markings on |he hol(h'r an(t install (orre(t]v.
replaced or they may have been Rut)lace batteries if they are/)1(/.
installed incorrectly.
Timer not reset Reset button has built-in time delay. Reset timer 1)} holding down reset bHttoll fl)r ,_ seconds.
Chlorine taste and/or The filter cartridge is no Rel)lace FXIITC filter cartridge.
odor in the product water longer removing clflorine
from the water supply.
I:XHSC Filter (pleated paper) is * If (blorine red mtion is desired, (hange to FXItTC filter cartridge.
installed, which does not remove
chlorhle.
Fittings are leaking Not enough sealing tape Unscrew fitting from head and remove/)1(/sealing tal)e. Add new sealing
between fitting and head on fittings, tal)e to the fitting.
Fitting has become loose. Install mounting bracket it not used.
Tighten fittings with wrelwh.
Water dispenses The filter has been installed * A three-month change-out t)eriod is re(omnlended.
very slowly for too long. Ret)la(e fiher (artridge.
The filter cartridge has * Itigh se(fiment levels can (ause wemature clogging.
become clogged. Rel)lace filter (artridge.
Fittings are leaking Piping system is not * This fitting is designed lot 3,/4" cot)t)er pipe only. Consuh a licensed
between titting and pipe 3/4" copper pipe. t)hunt)er if other t)it)ing is used.
Compression nut has become loose. Tighten the comt)ression mu with wrench while holding ()flier half of
/hdng with se(ond wren(tl,
Canister is difficult hflet water supply still on. Shut off inlet water and t)ush red t)ressure relict button.
to remove
Internal water pressure has not P/Istl red [)resstlre relict b/ltton.
been relieved.
Leaking between Seal O-ring is missing or damaged. Rut)lace ()-ring (Part #IIDRIN(',)
canister and head
Cauister is loose. Turv, oil _'_lter SUl)l)ly.
Press red t)ressure relief t)utton.
Tighten (anisier with (auisier _vren(b.