Manual
ge.com
Problem Possible Causes What To Do
Salty tasting or Unit not sanitized • Complete the Sanitization Procedureson page 12.
brown/yellow colored • At completion of recharge cgcle (approx.2 hrs),run water
water after installation from faucets to purge the salty wateE
Low water pressure Check pressure.
• Drain height 8' or less,pressureshould be minimum of 20 psi,
• Drain height above 8', pressureshould be minimum of 50 psi.
Restricted drain hose • Clean and reconnect hose.
• Check for kinksin drain line.
Brown/gellow Unit was idlefor a period of time • Complete the Sanitizotion Procedureson page 12.
colored water
Resinbeads showing Cracked distributor • Call for service.
up in drinking water
and sink
Soundsyou might hear Running water from the unit • Thisisnormal.
into a drain during recharge
Water has air bubbles Air in sgstem after installation • Will go awag after it runs for a while.
and is cloudy
Error Code on control Wiring mag have worked loose • Seepage 16for details.
in the control
• Unplug transformer`
• Remove control cover,release clips on side.
• Checkfor loose/incorrect wiring connections to electronic
board or switch. Reconnect as required.
• Reassemblecontrol cover`
• Plugin Transformer,
• Wait six minutes for Error Codeto reappear`
• If Error Code reappears,call for service.
25