Timer/Softener, Service Checkout Procedure
Ifgou are not getting soft water, and an error code is not displaged, use the procedures below to
find the problem. First make the following visual checks:
VISUALCHECKS: IT] Is there electrical power to the outlet the water softening sgstem transformer
_-J is plugged into?
FZ]Is there sufficient salt in the storage tank?
E]ls the plumbing bgpass valve directing water for soft water service?
F_-]ls the valve drain hose open to the drain, not more than 8' above the
/
softener, and unobstructed? Ifhose is above 8, see page 8, section 5.
If gou do not find a problem with the visual checks, continue below.
TIMER
DISPLAY
BLANK.
TIMERSHOWS
WRONG TIME AND
DAY,AND/OR IS
FLASHING.
• REPAIRAS
Checkelectrlcal I [NOPOWER 1 I ......
power to control
(outlet, transformer, I-_L_JPOWER OKI . i
power cable, all |_1 .......... I'-_" TIMER
connections). | I DEFECTIVE
fl Electrical _ Investigate reason for
power
was
off. Resetthe correct
power oss.
| time of dag.
Do manual
diagnostics
to verifg
proper
function.
TIMER DISPLAYSHOWS
CORRECTTIME AND DAY
AND IS STEADY.
Do manual
diagnostics.
17