Before you call for service...
_ Troubleshooting Tips
Problem
Salty tasting or
brown/yellow colored
water after installation
Possible Causes
Unit not sanitized
What To Do
Complete the Sanitization Procedureson page 14.
At completion of recharge cgcle (approx.2 hrs),run water
from faucets to purge the salty water.
Low water pressure
Check pressure.
Drainheight 8' or less,pressureshould be minimum of 20 psi.
Drainheight above 8', pressureshould be minimum of 50 psi.
Restricted drain hose Cleanand reconnect hose.
Check for kinks indrain line.
Brown!yellow
colored water
Unit was idle for a period of time Complete the Sanitization Procedureson page !4.
Resin beads showing
up in drinking water
and sink
Cracked distributor Callfor service.
Sounds you might hear Running water from the unit Thisis normal.
into a drain during recharge
Water has air bubbles Air in sgstemafter installation Will go awag after it runs for a while.
and is cloudy
Error Code an control Wiring mag have worked loose
in the control
Seepage 18for details.
Unplug transformer.
Removecontrol cover,release clips on side.
Check for loose/incorrect wiring connections to electronic
board or switch. Reconnectas required.
Reassemblecontrol cover.
PluginTransformer.
Wait six minutes for Error Codeto reappear.
If ErrorCode reappears,call for service.
Blue light flashing
When power applied Control needs to be programmed Seethe Programming the Contro! section, page !0.
to the system (a power outage mag have occurred}
If"DAYS TO EIvIpTY'' Low salt level, less than 15 dags Fillwith salt.
is flashing Reset salt level.
If"Err" in displag Electrical problem with sgstem Seepage 18for details.
Seeprocedure above, Errorcode on control.
24