Manual

5A CONNECTINGA RIGIDVALVEDRAINTUBE
To adapt a copper drain robe to the soitener, buy ?t compression fitting (1/4 NPT x 1//9" O.D.
robe) and needed tuhing Ii'om your local hardware store.
6 INSTALLTHEBRINETANKOVERFLOWFITTINGSANDHOSE
Insert tile rubber g_'ommet into tile 3/4" diameter hole in tile brine tamk sidewall as shox_]
in Fig. 5.
Push tile end of the hose adapter elbow into tile g_'ommet as shown in Fig. 5.
Attach a length of hose (use remaining hose In)m Stop 5) m tile hose adaptor elbow Use a hose
clamp m hold it ill place.
I_ocam tile other end of tile hose at tile drain point. DO NOT ELEVATE this hose higher than
tile e/bo_s on tile brine rank.
IMPORTANT:DONOTTEEOVERFLOWHOSETOVALVEDRAINHOSE
NOTE:Thisdrafil is lOTsafetyonly II the cabinet (brine umk) should o\erfiII with water;tile excess
iscarried to tile drain
7 INSTALLGROUNDINGCLAMP
If pluml)ing is me'ud, to maintain electrical ,_'omld continuity in tile house cold water piping, install
the included ground clamp as shown in Fig. 6.
Clean pipe with emer> paper in tile area _dlere tile clamp is to he installed.
Instal[ grounding clamps as sD)x_, making sure damps fit li'eely around pipe.
Make sure lock x_:tsheris ill place.
Handtighten scre_, then one more flfll mrn with scre_x(hg'el_
/VOTE:W[len repladng m_existing soltenel; also replace grounding clamps.
If removing soltener completel b hard-phmlb tile water line with same t}pe of pipes as the original
u) assure plumbing integ_'iV and ground continui V o\er tile [ifieof tile home.
8 FLUSHPIPES,EXPELAIRFROMSOFTENERANDTESTYOURINSTALLATIONFOR
WATERLEAKS
A CAUTION:To avoid water or Mrpressure dmnage to softener inner parts, be sure to
do the following steps in exact order.
Fully open 2 cold soft water faucets nearby the softener.
Place bypass valve in "bypass" position by pushing the stem inwm'd.
Fully open the house main water pipe shutoff valve. Observe a steady, flow from both faucets
opened in step A, above.
Place bypass valve in the "service" position [XA_CTLYas follows. I_2EP soFT WATER
FAUCETS OPEN.
SLOB_LYpull or slide the valve stem (ou 0 towaxd the service position, pausing several times to
allow the softener to pressurize slowly.
After about 3 minutes, open a HOT water faucet for 1 minute, or mllil all air is expelled, then
close. NOTE: If water appears cloudy or has salF "utste,allow to run fi)r several more minutes, or
until clem_
Cli)se all water faucets.
Check your phunbing won for leaks and fix rigbt away if any axe fomld. Be sure to observe
previous caution notes.
Tunl on file gas or elecWic supply to the water heater. Light file pilot, if applicable.
1/4"NPTthread
Compressionfitting
1/4NPTxI/2" O.D.
tube(notprovided)
/
!
Cutbarbsfromvalvedrain 1/2"outside
elbow{pullclipandremove diametercopper
drainvalveelbowfromvalve) tube(notprovided)
Fig. 5" -_
_:_,_..__i Hoseadapter
Hoseclamp
Tovalveinlet
GroundClam
Fromvalveoutlet
9 ADDWATERANDSALTTOTHEBRINETANK
I.it't tile salt hole co_r Add about 3 g'allons of _<lter into the rank. Do
not add into tile bfinewe/1.
Fill rank with NUGGET, PELI.ET or coarse SOI.AP, wamr softener salt
with a purity, of99.5% or higher Do not use rock, block, gramflated
and ice cream-making salts, or salt with iron-removing additives
(except for Diamond C_ystal° Red.Out c'_hrand salt). Maximum silt
storage capacity is approximatel} 200 [bs. Keep tile salt hole cover
dosed unless ser\icing the unit or refilling with salt.
/VOTE:If the softener is installed ill a humid basement or other damp
area, it is hetter to Fillthe rank with less salt, more frequently. Eighty to
100 [bs. of salt will last lot se\eral months, depending on _<lmr
hardness, Imni/y size and water soltening s)rsmln model.
10.CONNECTTOELECTRICALPOWER
To gain access to tile transfi_rmer/power cord assembly, remo_ tile
salt hole co\er li'om tile softener. Unclip tile robs on tile rear of tile
top co\er and romm tile co\er upwards to remo_ e. DO NOT PUII,
OR DISCONNECT WIRING.
Tile softener _)rks on 24 voh4;OHz electric power: Tile included
transformer dlanges standard 120aok AC house power to 24 \ohs.
Plug, the tra_sfonner into a 120-volt outlet only. Be sure the outlet is
ah_a}s li\e so it can not he _vikhed offb_ mistake.
Replace tile mp coxe_:
Replace tile salt hole covel:
7