Problem Possible Causes What To Do
Salty tasting or Unit not sanitized Conq)lete the Sanitization Procedures on page 10.
brown/yellow colored At ('(nnl)letion of recharge, cycle, (apl)rox. _2hLO,_run water
water after installation ti'()m ti_ucets to purge the salty water:
Low water pressure Check px'esstlx'e.
" Drain height 8' or less, pressure shotfld be minimum oI 20 psi.
Drain height above 8', pressure should be minimum ot 50 psi.
Restricted drain hose (]lean and reconnect hose.
Check fin" kinl<s in drain line.
Brown/yellow Unit was idle for a period of thne (}omplete the Sanitization Procedures on page 10.
colored water
Resin beads showing Cracked distributor Call tot se_i('e.
up in drinking water
and sink
Sounds you might hear Rm_fing water from the unit This is hernial.
into a drain during recharge
Water has air bubbles Air in system after installation _,_]11go away after it rtms fin" a while.
and is cloudy
Error Code on control Wiring may have worked loose See page 14 fin" details.
hi the control
UIq)lug ti'anslblmei:
Remove control cove_; release clips on side.
Check fin" loose/incorrect wiring connections to electronic
board or swit('h. Reconnect as required.
Reassemble control cove_:
Plug in Transfinme_:
X.Vaitsix minutes t0r Error Code to reappear;
If Error Code reappeaI_, call fin" service.
Blue light flashing
When power applied Conl*ol needs to be pmgrmnmed See the Programming the Control section, page 8.
to the system (a power outage may have occurred)
If "DAYS TOEMPTY" Low salt level, less thmi 15 days Ell with salt.
is flashing Reset salt lexel.
If "Err"in display l?TJectrical problem with system See page 14 fin" details.
See procedure above, Error code on control.