Manual

Before you call for service...
Troubleshooting Tips
Problem Possible Causes What To Do
Salty tasting or Unit not sanitized * Complete the Sanitization Procedureson page 12.
brown/yellow colored At completion of recharge cucle (approx.2 hrs),run water
water after installation from faucets to purge the salty water.
Low water pressure Check pressure.
Drain height 8' or less,pressureshould be minimum of 20 psi.
Drain height above 8', pressureshould be minimum of 50 psi.
Restricted drain hose Clean and reconnect hose.
Check for kinksin drain line.
Brown/yellow Unit was idle for a period of time Complete the Sonitizotion Procedureson page 12.
colored water
Resinbeads showing Cracked distributor Callfor service,
up in drinking water
and sink
Soundsgou might hear Running water from the unit Thisis normal.
into a drain during recharge
Water has air bubbles Air in sgstem after installation Will go away after it runs for a while.
and is cloudy
Error Codeon control Wiring mag have worked loose Seepage 16for details.
in the control
Unplug transformer,
Remove control cover,release clips on side.
Checkfor loose/incorrect wiring connections to electronic
board or switch. Reconnect asrequired.
Reassemblecontrol cover.
Plugin Transformer,
Wait six minutes for Error Codeto reappear,
If Error Code reappears,call for service.
22