Technical Specifications

10000 Series Double Ported Globe Valves | 5
0.75 .88/.80 0.5 .8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 8
1
.88/.80 0.5 .8 1.6 2.4 3.2 4.0 4.8 5.6 6.4 7.2 8
1.06/.98 0.5 1.2 2.4 3.6 4.8 6 7.2 8.4 9.6 10.8 12
1.06/.98 0.8 1.1 2.2 3.3 4.4 5.5 6.6 7.7 8.8 9.9 11
1.5
1.5/1.42 0.8 2.8 5.6 8.4 11.2 14 16.8 19.6 22.4 25.2 28
2
1.43/1.35 0.8 1.9 3.8 5.7 7.6 9.5 11.4 13.3 15.2 17.1 19
2.00/1.90 0.8 4.8 9.6 14.4 19.2 24 28.8 33.6 38.4 43.2 48
3
1.87/1.78 1.5 4.4 8.8 13.2 17.6 22 26.4 30.8 35.2 39.6 44
2.62/2.53 1.5 11 22 33 44 55 66 77 88 99 110
4
2.37/2.28 1.5 7.8 15.6 23.4 31.2 39 46.8 54.6 62.4 70.2 78
3.50/3.40 1.5 19.5 39 58.5 78 97.5 117 136 156 175 195
6
3.50/3.40 2 18 36 54 72 90 108 126 144 162 180
5.25/5.15 2 45 90 135 180 225 270 315 360 405 450
8
4.62/4.53 2.5 30 60 90 120 150 180 210 240 270 300
7.00/6.87 2.5 75 150 225 300 375 450 525 600 675 750
10
5.25/5.15 2.5 46 92 138 184 230 276 322 368 414 460
8.75/8.62 2.5 116 232 348 464 580 696 812 928 1044 1160
12
6.37/6.25 3.5 65 130 195 260 325 390 455 520 585 650
10.50/10.34 3.5 162 324 486 648 810 972 1134 1296 1458 1620
C
V
and F
L
versus Travel
Flow Characteristic: LINEAR
Percent of Travel
Rated C
V
F
L
Valve
Size
Orifice
Diameter
Travel
inch
Full Area
10 20 30 40 50 60 70 80 90 100
.63 .64 .65 .70 .77 .85 .90 .90 .89 .88
.63 .64 .65 .70 .75 .80 .82 .82 .81 .80
Contoured Trim
ASME Class 150 to 600
Reduced Area
inch
inch