Brochure
VRF
COMMERCIAL AC DUCTLESS
WATER HEATERS WATER TREATMENT
ROOM AC
SPECIFICATIONS
116
See page 106 for warranty information.
See page 106 for warranty information.
geappliances.com
117116
DUCTLESS MULTI-ZONE SOLUTIONS
Outdoor
HAIER
ENERGY
STAR®
CAPACITY
STANDARD
CONTROLLER
OPTIONAL
CONTROLLER7K 9K 12K 18K 24K
ARCTIC MULTI
2U20EH2 (2 Zone) YES
AW07EH†
AW07LC†
AW09EH†
AW09LC†
AW12EH†
AW12LC† AW18EH† AW24LC† WJ01X24721*
YR-E17***
QACT17A***
YR-E16B***
3U24EH2 (3 Zone) YES AD07SL
AD09SL
USYM09U**
AD12SL
USYM12U**
AD18SL
USYM18U**
AM24LP
USYM24U**
YR-E17
QACT17A
YR-E16B
Purchase
Separately
YR-E17
QACT17A
YR-E16B
4U36EH2 (4 Zone) YES
AB09SC
USYF09U**
AB12SC
USYF12U**
AB18SC
USYF18U** AL24LP WJ01X24721*
YR-E17
QACT17A
YR-E16B
FLEXFIT MULTI
2U18MS2 (2 Zone) AW07LC† AW09LC† AW12LC† AW18LC† AW24LC† WJ01X24721*
YR-E17***
QACT17A***
YR-E16B***
3U24MS2 (2-3 Zone) AD07SL
AD09SL
USYM09U**
AD12SL
USYM12U**
AD18SL
USYM18U**
AM24LP
USYM24U**
YR-E17
QACT17A
YR-E16B
Purchase
Separately
QACT17A
YR-E16B
4U36MS2 (2-4 Zone)
AB09SC
USYF09U**
AB12SC
USYF12U**
AB18SC
USYF18U** AL24LP WJ01X24721*
YR-E17
QACT17A
YR-E16B
* Remote controller WJ01X24721 and WJ26X27153 are shipped with indoor unit. Additional controllers can be purchased via parts account.
**Built-In WiFI
***Requires WK-B adapter.
†Compatible with WiFi Adapter (QAWF01A)
Matching one outdoor unit with a variety of multiple indoor units provides contractors unprecedented application flexibility.
DUCTLESS MULTI-ZONE MATCHING CHART
2U18MS2VHB
2U20EH2VHA
HAIER
COMBINATIONS
TOTAL SYSTEM
CAPACITYUNIT A UNIT B
TWO ZONE
7K 7K 14K
7K 9K 16K
9K 9K 18K
7K 12K 19K
9K 12K 21K
12K 12K 24K
3U24MS2VHB
3U24EH2VHA
HAIER
COMBINATIONS
TOTAL SYSTEM
CAPACITYUNIT A UNIT B UNIT C
TWO ZONE
7K 7K 14K
7K 9K 16K
9K 9K 18K
7K 12K 19K
9K 12K 21K
12K 12K 24K
7K 18K 25K
9K 18K 27K
12K 18K 30K
THREE ZONE
7K 7K 7K 21K
7K 7K 9K 23K
7K 9K 9K 25K
7K 7K 12K 26K
9K 9K 9K 27K
7K 9K 12K 28K
9K 9K 12K 30K
7K 12K 12K 31K*
7K 7K 18K 32K*
9K 12K 12K 33K*
* All indoor units must be FlexFit models
4U36MS2VHB
4U36EH2VHA
HAIER
COMBINATIONS
TOTAL SYSTEM
CAPACITYUNIT A UNIT B UNIT C UNIT D
TWO ZONE
9K 18K 27K
12K 18K 30K
7K 24K 31K
9K 24K 33K
12K 24K 36K
18K 18K 36K
24K 18K 42K
24K 24K 48K*
THREE ZONE
9K 9K 9K 27K
7K 9K 12K 28K
9K 9K 12K 30K
7K 12K 18K 31K
7K 7K 12K 32K
9K 12K 12K 33K
7K 9K 18K 34K
9K 9K 18K 36K
12K 12K 12K 36K
7K 12K 18K 37K
7K 7K 24K 38K
9K 12K 18K 39K
7K 9K 24K 40K
9K 9K 24K 42K
12K 12K 24K 42K
7K 12K 18K 43K
9K 9K 27K 45K
12K 12K 24K 48K*
12K 18K 18K 48K*
FOUR Zone
7K 7K 7K 7K 28K
7K 7K 7K 9K 30K
7K 7K 9K 9K 32K
7K 7K 7K 12K 33K
7K
9K 9K 9K 34K
7K 7K 9K 12K 35K
9K 9K 9K 9K 36K
7K 9K 9K 12K 37K
7K 7K 12K 12K 38K
7K 7K 7K 12K 39K
9K 9K 9K 12K 39K
7K 9K 12K 12K 40K
7K 7K 9K 18K 41K
9K 9K 12K 12K 42K
7K 9K 9K 18K 43K
7K 12K 12K 12K 43K
7K 7K 12K 18K 44K
7K 7K 7K 24K 45K
9K 9K 9K 18K 45K
9K 12K 12K 12K 45K
7K 7K 9K 24K 47K
9K 9K 12K 18K 48K*
12K 12K 12K 12K 48K*
*All indoor units must be FlexFit models
HAIER DUCTLESS ARCTIC SERIES MULTI ZONE SYSTEMS
Outdoor UnitS
HAIER
2 ZONES 3 ZONES 4 ZONES
2U20EH2VHA 3U24EH2VHA 4U36EH2VHA
SPECIFICATIONS
Compressor Type DC Inverter Driven Rotary DC Inverter Driven Rotary DC Inverter Driven Rotary
Voltage/Cycle/Phase 208-230/60/1 208-230/60/1 208-230/60/1
Operating range (°F) Heating -15 -75° -15-75° -15-75°
Cooling 0-115° 0-115° 0-115°
COOLING NON-DUCTED
Rated capacity BTU/hr 18,000 21,000 34,000
Capacity range BTU/hr 7,000-20,000 6,000-23,600 6,000-38,000
Rated power input W 1,448 1,760 2,740
SEER/EER 17/12. 5 18.5/12.5 20 /12.5
COOLING DUCTED
Rated capacity BTU/hr 18,100 21,000 34,400
Capacity range BTU/hr 6,000-19,000 6,000-22,300 6,000-37,000
Rated power input W 1,724 2,000 2,740
SEER/EER 15/10.5 15/10.5 17.00 /10.00
HEATING NON- DUCTED
Rated heating capacity 47°F BTU/hr 20,000 24,000 36,000
Heating capacity range BTU/hr 8,000-23,000 8,000-30,600 8,000-39,000
Rated power input W 1,504 1,572 2,710
HSPF 11 11 11
COP @ 5°F 2.0 2.0 2.0
Max. heating capacity 5°F BTU/hr 23,500 24,000 36,000
Max. heating capacity -15°F BTU/hr 17, 250 18,000 25,700
HEATING DUCTED
Rated heating capacity 47°F BTU/hr 20,000 22,000 35,000
Heating capacity range BTU/hr 8,000-21,000 8,000-28,600 8,000-39000
Rated power input W 2,255 2,230 2,710
HSPF 10.5 10.5 10.5
COP @ 5°F 1.9 1.9 1.9
Max. heating capacity 5°F BTU/hr 21,000 23,200 35,000
Max. heating capacity -15°F BTU/hr 16,300 17,1 00 25,200
POWER SUPPLY
Voltage, Cycle, Phase V/Hz/- 208-230/60/1 208-230/60/1
Wire size between ID and OD 14/4 AWG Stranded 14/4 AWG Stranded 14/4 AWG Stranded
Maximum fuse size A 25 25 40
Minimum circuit amp A 15 16 30
OUTDOOR UNIT
Base Pan Heater Standard Standard Standard
Outdoor fan speed RPM 300-900 300-900 300-900
Outdoor noise level dB 56 56 55
Dimension: height in (mm) 33.1(840) 33.1(840) 38.0 (965)
Dimension: width in (mm) 37. 3(948) 37. 3(948) 37.4 (950)
Dimension: depth in (mm) 13.4(340) 13.4(340) 14.6(370)
Weight (Ship/Net)- lbs (kg) 202 . 3/1 85.6 (91.7/84 . 2) 205.9/189.5 (93.4/85.9) 241/221 (109.7/100.6)
Connectable indoor unit quantity 2 2 or 3 2 3 or 4
REFRIGERANT LINES
Connections Flare Flare Flare
Liquid O.D. in 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4
Suction O.D. in 3/8 3/8 3/8 3/8 1/2 3/8 3/8 3/8 1/2
Factory charge Oz 99 99 113
Maximum line length Ft / m 164/50 196/60 230/70
Maximum height Ft / m 50/15 50/15 50/15
Maximum line length for each
individual indoor unit Ft / m 82/25 82/25 82/25
With the integration of Haier Heat Plus technology, the Arctic Series provides an exceptional experience for year-round
comfort. The system is capable of providing 100% rated heating capacity at 5°F and toasty warm air at -15°F.