Performance Data Sheet
Model: GE Appliances XWFE 
Ŷ6\VWHPFHUWLILHGE\,$30257DJDLQVW16)$16,6WDQGDUGVDQG3IRUWKHUHGXFWLRQRIFODLPVVSHFLILHGRQWKHSHUIRUPDQFHGDWDVKHHWDQG
at iapmort.org.
Ŷ$FWXDOSHUIRUPDQFHPD\YDU\ZLWKORFDOZDWHUFRQGLWLRQV
,WLVHVVHQWLDOWKDWWKHPDQXIDFWXUHU¶VUHFRPPHQGHGLQVWDOODWLRQ
maintenance and filter replacement requirements be carried out for the 
SURGXFWWRSHUIRUPDVDGYHUWLVHG6HH,QVWDOODWLRQ0DQXDOIRU:DUUDQW\
information.
Application Guidelines/Water Supply Parameters
6HUYLFH)ORZ 0.5 gpm (1.89 lpm)
Water Supply Potable Water
Water Pressure 25-120 psi (172-827 kPa)
Water Temperature ))&&
Capacity 170 gallons (643.5 liters)
Substance Tested for Reduction
,QIOXHQWFKDOOHQJH
concentration 
(mg/L)
Maximum permissible 
product water 
concentration (mg/L)
Avg % 
Reduction
Chlorine Taste and Odor 2.0 mg/L +/- 10% N/A > 99
Chloramine Taste and Odor 3.0 mg/L +/- 10% 0.5 > 99
3DUWLFXODWH&ODVV, At least 10,000/mL N/A 91.4
Cysts 50,000/L N/A > 99.99
Lead 0.15 0.01 98.85
Mercury 0.006 0.002 96.95
Asbestos 107 to 108 fibers/ L N/A > 99
Toxaphene  0.015 +/- 10% 0.003 86.95
VOC (Chloroform surrogate chemical) 0.300 0.015 > 99
Alachlor 0.050 0.001 > 98
$WUD]LQH 0.100 0.003 > 97
%HQ]HQH 0.081 0.001 > 99
Carbofuran 0.190 0.001 > 99
carbon tetrachloride 0.078 0.0018 98
FKORUREHQ]HQH 0.077 0.001 > 99
chloropicrin 0.015 0.0002 99
' 0.110 0.0017 98
GLEURPRFKORURSURSDQH'%&3 0.052 0.00002 > 99
R'LFKORUREHQ]HQH 0.08 0.001 > 99
S'LFKORUREHQ]HQH 0.040 0.001 > 98
1,2-dichloroethane 0.088 0.0048 95
1,1-dichloroethylene 0.083 0.001 > 99
cis-1,2-dichloroethylene 0.170 0.0005 > 99
trans-1,2-dichloroethylene 0.086 0.001 > 99
1,2-dichloropropane 0.080 0.001 > 99
cis-1,3-dichloropropylene 0.079 0.001 > 99
dinoseb 0.170 0.0002 99
Endrin 0.053 0.00059 99
(WK\OEHQ]HQH 0.088 0.001 > 99
HWK\OHQHGLEURPLGH('% 0.044 0.00002 > 99
bromochloroacetonitrile 0.022 0.0005 98
dibromoacetonitrile 0.024 0.0006 98
dichloroacetonitrile 0.0096 0.0002 98
trichloroacetonitrile 0.015 0.0003 98
1,1-dichloro-2-propanone 0.0072 0.0001 99
1,1,1-trichloro-2-propanone 0.0082 0.0003 96
heptachlor (H-34, Heptox) 0.025 0.00001 > 99
heptachlor epoxide 0.0107 0.0002 98
hexachlorobutadiene 0.044 0.001 > 98
hexachlorocyclopentadiene 0.060 0.000002 > 99
Lindane 0.055 0.00001 > 99
methoxychlor 0.050 0.0001 > 99
pentachlorophenol 0.096 0.001 > 99
VLPD]LQH 0.120 0.004 > 97
Styrene 0.150 0.0005 > 99
1,1,2,2-tetrachloroethane 0.081 0.001 > 99
Tetrachloroethylene 0.081 0.001 > 99
Toluene 0.078 0.001 > 99
2,4,5-TP (silvex) 0.270 0.0016 99
tribromoacetic acid 0.042 0.001 > 98
7ULFKORUREHQ]HQH 0.160 0.0005 > 99
1,1,1-trichloroethane 0.084 0.0046 95
1,1,2-trichloroethane 0.150 0.0005 > 99
trichloroethylene 0.180 0.0010 > 99
bromoform 0.300 0.015 95
bromodichloromethane 0.300 0.015 95
chlorodibromomethane 0.300 0.015 95
xylenes 0.070 0.001 > 99
Meprobamate 400 +/- 20% 60 > 99
Atenolol 200 +/- 20% 30 > 99
&DUEDPD]HSLQH 1400 +/- 20% 200 > 99
'((7 1400 +/- 20% 200 > 99
Metolachlor 1400 +/- 20% 200 > 99
Trimethoprim 140 +/- 20% 20 > 99
Linuron 140 +/- 20% 20 > 99
TCEP 5000 +/- 20% 700 > 99
TCPP 5000 +/- 20% 700 > 99
Phenytoin 200 +/- 20% 30 > 99
,EXSURIHQ 400 +/- 20% 60 > 99
Naproxen 140 +/- 20% 20 > 99
Estrone 140 +/- 20% 20 > 99
Bisphenol A 2000 +/- 20% 300 > 99
Nonyl phenol 1400 +/- 20% 200 > 99
3)2$3)26 1.5 mg/L +/- 10% 0.07 99.25
NOTE: While the testing was performed under standard 
laboratory conditions, actual performance may vary. 
5HSODFHPHQW&DUWULGJH;:)()RUHVWLPDWHGFRVWVRI
replacement elements please call 1.877.959.8688 or visit our 
website at gewaterfilters.com.
WARNING
 To reduce the risk associated with 
ingestion of contaminants:
•  Do not use with water that is microbiologically unsafe 
or of unknown quality without adequate disinfection 
before and after the system. Systems certified for cyst 
reduction may be used on disinfected water that may contain 
filterable cysts. 
NOTICE
To reduce the risk of water leakage or flooding, and to 
ensure optimal filter performance:
• Read and follow use instructions before installation and 
use of this system.
,QVWDOODWLRQDQGXVHMUST comply with all state and local 
plumbing codes.
• Do not install if water pressure exceeds 120 psi (827 
N3D,I\RXUZDWHUSUHVVXUHH[FHHGVSVLN3D\RX
must install a pressure-limiting valve. Contact a plumbing 
professional if you are uncertain how to check your water 
pressure. 
• Do not install where water hammer conditions may occur. 
,IZDWHUKDPPHUFRQGLWLRQVH[LVW\RXmust install a water 
hammer arrester. Contact a plumbing professional if you are 
uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum 
RSHUDWLQJZDWHUWHPSHUDWXUHRIWKLVILOWHUV\VWHPLV)
(38º C).
•  Protect filter from freezing. 'UDLQILOWHUZKHQWHPSHUDWXUHV
GURSEHORZ)&
• Change the disposable filter cartridge every six months or 
sooner if you observe a noticeable reduction in water flow 
rate.
)DLOXUHWRUHSODFHWKHGLVSRVDEOHILOWHUFDUWULGJHDW
recommended intervals may lead to reduced filter 
performance and cracks in the filter housing, causing water 
leakage or flooding.
7KLV6\VWHPKDVEHHQWHVWHGDFFRUGLQJWR16)$16,
53, 401 and P473 for the reduction of the substances listed 
below. The concentration of the indicated substances in 
water entering the system was reduced to a concentration 
less than or equal to the permissible limit for water leaving 
WKHV\VWHPDVVSHFLILHGLQ16)$16,DQG3
;:)(6\VWHPLVFHUWLILHGE\,$302
57DJDLQVW16)$16,6WDQGDUGV
53, 401, and P473 for the reduction of 
claims specified on the performance 
data sheet and at iapmort.org.