Quick Start Manual
4
Installation Instructions
3
EXHAUST INFORMATION
WARNING - IN CANADA AND IN THE
UNITED STATES, THE REQUIRED EXHAUST DUCT
DIAMETER IS 4 in (102mm). DO NOT USE DUCT
LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
• Reduce the dryer life.
$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR RESPONSIBILITY.
Problems due to incorrect installation are not covered by
the warranty.
Remove and discard existing plastic or metal foil transition
duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of
bends of the exhaust system depends upon the type of duct,
QXPEHURIWXUQVWKHW\SHRIH[KDXVWKRRGZDOOFDSDQGDOO
conditions noted below. The maximum duct length for rigid
metal duct is shown in the table below.
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90°
Elbows
Rigid
Metal
Rigid
Metal
90 Feet
60 Feet
45 Feet
35 Feet
25 Feet
60 Feet
45 Feet
35 Feet
25 Feet
15 Feet
0
1
2
3
4
Use only for short
run installations
EXHAUST LENGTH
• )RUHYHU\H[WUDHOERZUHGXFHWKHDOORZDEOHYHQWV\VWHP
OHQJWKE\IW
• 7ZRHOERZVZLOOEHWUHDWHGOLNHRQHHOERZ
• )RUWKHVLGHH[KDXVWLQVWDOODWLRQVDGGRQHHOERZWRWKH
chart.
• The total vent system length includes all the straight portions
DQGHOERZVRIWKHV\VWHPWUDQVLWLRQGXFWLQFOXGHG
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of birds or other wildlife.
7HUPLQDWLRQVKRXOGSUHVHQWPLQLPDOUHVLVWDQFHWRWKHH[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFHWRSUHYHQW
clogging.
• Never install a screen in or over the exhaust duct. This could cause lint build up.
•
:DOOFDSVPXVWEHLQVWDOOHGDWOHDVWLQDERYHJURXQGOHYHORUDQ\RWKHUREVWUXFWLRQZLWKWKHRSHQLQJSRLQWHGGRZQ