Specification

For answers to your Monogram, GE Café
Series, GE Profile
Series or
GE Appliances product questions, visit our website at geappliances.com
or call GE Answer Center
®
Service, 800.626.2000.
Specification Created 8/16
GFD49ERPK/ERSK
GE Appliances 8.3 cu. ft. capacity RightHeight
Design Front Load electric
ENERGY STAR
®
Dryer with steam
DRYER EXHAUSTING INFORMATION – Metal duct only.
For complete information, see installation instructions packed with your dryer.
DUCTING MATERIALS: For best performance, this dryer should be vented with 4" diameter all rigid
metal exhaust duct. If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting
can be used (Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the
house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may be used
ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be used AND
where a 4" diameter can be maintained throughout the entire length of the transition duct. Please see
installation instruction packed with your dryer for complete instructions when using flexible metal
(foil type) ducting.
EXHAUST LENGTH CALCULATION:
1. Determine the number of 90° turns needed for your installation. If you exhaust to the
side or bottom of dryer, add one turn.
2. The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is
shown in the table.
A turn of 45° or less may be ignored. Two 45° turns within the duct length should be
treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
CAUTION: For personal safety do not terminate exhaust into a chimney, under any enclosed house floor (crawl
space), or into an attic, since the accumulated lint could create a fire hazard or moisture could cause damage.
Never terminate the exhaust into a common duct or plenum with a kitchen exhaust, since the combination of
lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, etc. The wall
cap must also be located at least 12" above the ground or any other obstruction with the opening pointed down.
FOR MORE INFORMATION ON VENTING KITS AND ACCESSORIES,
PLEASE CALL 1-800-GE-CARES.
BEST PERFORMANCE
Maximum length
of 4" dia rigid
metal duct
Exhaust hood type
Domestic dryer models
Number
of 90°
turns
A
4"
opening
B
2-1/2"
opening
8.3 cu. ft. capacity
models electric dryers
0 90 ft. 60 ft.
1 60 ft. 45 ft.
2 45 ft. 35 ft.
3 35 ft. 25 ft.
4 25 ft. 15 ft.
A
B
2-1/2
4
GE Dryer Vent
A
B
2-1/2
4
GE Dryer Vent
A
DRYER EXHAUSTING INFORMATIONUSE METAL
DUCT ONLY VERTICAL AND HORIZONTAL DUCTING
Listed by
Underwriters
Laboratories