Troubleshooting
TROUBLESHOOTING
Before you call for service....  
Save time and money! Review the chart below first and you may not need to call for service.
CAUTION
 For your safety, DO NOT attempt repair of electrical wiring, controls, heating elements or 
RWKHUVDIHW\GHYLFHV5HIHUUHSDLUVWRTXDOL¿HGVHUYLFHSHUVRQQHO
Problem Possible Causes
What To do
OPERATION AND PERFORMANCE
Not enough or no hot 
water
Water temperature may 
be set too low
• See the Water Temperature Adjustment and Water Heater 
Capacity sections. (Pages 4 & 5)
Hot water usage pattern 
exceeds the capability of 
the water heater in current 
mode
• Change to different mode.
• Wait for the water heater to recover after an abnormal 
demand.
Cold water inlet tempera-
ture may be colder during 
the winter months
• This is normal. The colder inlet water takes longer to heat.
• Consider increasing the set temperature as described in 
the Water Temperature Adjustment section.
Leaking or open hot wa-
ter faucets
• Make sure all faucets are closed.
Long runs of exposed 
pipe, or hot water piping 
on outside wall
• Insulate piping.
Not enough clearance to 
allow air to circulate for 
the heat pump
0DNHVXUHXQLWLV´DZD\IURPWKHZDOODQGKDV´FOHDU-
DQFHDERYHWKHDLU¿OWHU
Room is too small or too 
cool, slowing heating 
performance
• Smaller rooms can lead to cooler room temperatures due 
to the heat pump cooling the air. If the room is smaller than 
FXIW¶[¶[¶LQVWDOOORXYUHGGRRUVRUVLPLODUYHQWLOD-
tion.
• Cooler room temperatures can cause the water heater to 
take longer to fully recover to the set temperature. Consider 
increasing the set temperature as described in the Water 
Temperature Adjustment section.
A fuse is blown, circuit 
breaker tripped, or elec-
tric service to your home 
may be interrupted 
• Replace fuse or reset circuit breaker.
• Contact the local electric utility.
Inadequate wiring • See the Installation Instructions.
Manual reset limit (TCO) •  See the Safety Controls section, see page 4.
Water Connections to 
unit reversed
• Correct piping connections.
Recirculating System 
Interference (if installed)
&KHFNÀRZUDWHLVQRWVHWWRRKLJK
• Insulate piping
Water is too hot Water temperature is set 
too high
• See the Water Temperature Adjustment section.
Electric control has failed • Call for service.
Water heater is mak-
ing the room cooler
Room is not vented 
properly or is too small
,IWKHURRPLVVPDOOHUWKDQFXIW¶[¶[¶WKHQLW
PXVWKDYHDORXYUHGGRRURURWKHUPHDQVWRDOORZDLUH[-
change with surrounding rooms.
Heat is removed from the 
air to heat the water
• This is normal.