Page:1/12 SAFETY DATA SHEET FOR INDUSTRIAL USE ONLY GE5040 Section 1. Product and company identification Product name : GE5040 Manufacturer/Importer/ Distributor Information : Momentive Amer Ind. 260 Hudson River Road Waterford NY 12188 Contact person : 4information@momentive.com Telephone : General information +1-800-295-2392 Emergency telephone number Supplier : CHEMTREC 1-800-424-9300 Section 2.
Page:2/12 GE5040 Response : IF exposed or concerned: Get medical attention. IF ON SKIN: Wash with plenty of soap and water. Take off contaminated clothing. Wash contaminated clothing before reuse. If skin irritation occurs: Get medical attention. IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing. If eye irritation persists: Get medical attention. Storage : Store locked up.
Page:3/12 GE5040 Ingestion : Wash out mouth with water. Remove dentures if any. Remove victim to fresh air and keep at rest in a position comfortable for breathing. If material has been swallowed and the exposed person is conscious, give small quantities of water to drink. Stop if the exposed person feels sick as vomiting may be dangerous. Do not induce vomiting unless directed to do so by medical personnel. If vomiting occurs, the head should be kept low so that vomit does not enter the lungs.
Page:4/12 GE5040 Personal precautions, protective equipment and emergency procedures For non-emergency personnel : For emergency responders : Environmental precautions : No action shall be taken involving any personal risk or without suitable training. Evacuate surrounding areas. Keep unnecessary and unprotected personnel from entering. Do not touch or walk through spilled material. Provide adequate ventilation. Wear appropriate respirator when ventilation is inadequate.
Page:5/12 GE5040 Section 8. Exposure controls/personal protection Control parameters Occupational exposure limits Ingredient name DIBUTYLTINDIACETATE Exposure limits OSHA PEL (1993-06-30) Calculated as Sn Time Weighted Average (TWA) 0.1 mg/m3 NIOSH REL (1994-06-01) Calculated as Sn Time Weighted Average (TWA) 0.1 mg/m3 OSHA PEL 1989 Vacated (1989-03-01) Calculated as Sn Time Weighted Average (TWA) 0.1 mg/m3 Form: Organic ACGIH TLV (1996-05-18) Calculated as Sn Time Weighted Average (TWA) 0.
Page:6/12 GE5040 Respiratory protection : involved and should be approved by a specialist before handling this product. Use a properly fitted, particulate filter respirator complying with an approved standard if a risk assessment indicates this is necessary. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator.
Page:7/12 GE5040 Section 10. Stability and reactivity Reactivity : Stable under normal conditions. Chemical stability : The product is stable. Possibility of hazardous reactions : Under normal conditions of storage and use, hazardous reactions will not occur. Conditions to avoid : No specific data. Incompatible materials : No specific data. Hazardous decomposition products : Under normal conditions of storage and use, hazardous decomposition products should not be produced. Section 11.
Page:8/12 GE5040 Specific target organ toxicity (repeated exposure) Product/ingredient name Category DIBUTYLTINDIACETATE Category 1 Route of exposure Aspiration hazard Product/ingredient name Distillates (petroleum), hydrotreated middle Target organs thymus Result ASPIRATION HAZARD - Category 1ASPIRATION HAZARD - Category 1ASPIRATION HAZARD Category 1 : Not available Eye contact Inhalation : : Skin contact Ingestion : : Causes serious eye irritation.
Page:9/12 GE5040 General Carcinogenicity Mutagenicity Teratogenicity Developmental effects Fertility effects : : : : : : No known significant effects or critical hazards. No known significant effects or critical hazards. No known significant effects or critical hazards. May damage the unborn child. No known significant effects or critical hazards. May damage fertility. Numerical measures of toxicity Acute toxicity estimates Route Oral Route Dermal Route Inhalation (vapors) ATE value 18,284.
Page:10/12 GE5040 products via a licensed waste disposal contractor. Waste should not be disposed of untreated to the sewer unless fully compliant with the requirements of all authorities with jurisdiction. Waste packaging should be recycled. Incineration or landfill should only be considered when recycling is not feasible. This material and its container must be disposed of in a safe way. Care should be taken when handling emptied containers that have not been cleaned or rinsed out.
Page:11/12 GE5040 Section 16. Other information Hazardous Material Information System III (U.S.A.) : 1 Health 1 Flammability 0 Physical hazards Caution: HMIS® ratings are based on a 0-4 rating scale, with 0 representing minimal hazards or risks, and 4 representing significant hazards or risks Although HMIS® ratings are not required on MSDSs under 29 CFR 1910.1200, the preparer may choose to provide them. HMIS® ratings are to be used with a fully implemented HMIS® program.
Page:12/12 GE5040 Version: 1.