Version: 1.10 Revision Date: 07/28/2016 GE5010 SAFETY DATA SHEET 1. Identification Product identifier: GE5010 Other means of identification Synonyms: SILICONE SEALANT Recommended use and restriction on use Recommended use: Silicone Elastomer Restrictions on use: Not known. Manufacturer/Importer/Distr ibutor Information : Momentive Performance Materials LLC 260 Hudson River Road Waterford NY 12188 Contact person : commercial.services@momentive.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Signal Word: No signal word. Hazard Statement: Causes serious eye irritation. Causes skin irritation. May cause an allergic skin reaction. May damage fertility or the unborn child. Precautionary Statement Prevention: Obtain special instructions before use. Do not handle until all safety precautions have been read and understood. Use personal protective equipment as required. Wear protective gloves. Wear eye protection/face protection.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Mixtures Chemical Identity CAS number Content in percent (%)* Notes Distillates, petroleum, hydrotreated middle 64742-46-7 7 - 13% # This substance has workplace exposure limit(s). Hexamethyldisilazane 999-97-3 1 - 5% No data available. TITANIUM DIOXIDE 13463-67-7 1 - 5% # This substance has workplace exposure limit(s). DIBUTYL TIN BIS ACETYLACETONATE 22673-19-4 0.1 - 1% # This substance has workplace exposure limit(s).
Version: 1.10 Revision Date: 07/28/2016 GE5010 Treatment: No data available. 5. Fire-fighting measures General Fire Hazards: No data available. Suitable (and unsuitable) extinguishing media Suitable extinguishing media: All standard extinguishing agents are suitable. Unsuitable extinguishing media: No data available. Specific hazards arising from the chemical: No data available. Special protective equipment and precautions for firefighters Special fire fighting procedures: No data available.
Version: 1.10 Revision Date: 07/28/2016 GE5010 8. Exposure controls/personal protection Control Parameters Occupational Exposure Limits Chemical Identity type Distillates, petroleum, hydrotreated middle Inhalable fraction. Distillates, petroleum, hydrotreated middle - Mist. TWA 5 mg/m3 US. ACGIH Threshold Limit Values (03 2015) REL 5 mg/m3 STEL 10 mg/m3 US. NIOSH: Pocket Guide to Chemical Hazards (2010) US. NIOSH: Pocket Guide to Chemical Hazards (2010) US.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Individual protection measures, such as personal protective equipment General information: Ventilation and other forms of engineering controls are preferred for controlling exposures. Respiratory protection may be needed for nonroutine or emergency situations. Eye/face protection: Safety glasses with side shields Skin Protection Hand Protection: Cloth gloves. Other: Wear suitable protective clothing and eye/face protection.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Density: Relative density: Solubility(ies) Solubility in water: Solubility (other): Partition coefficient (n-octanol/water) Log Pow: Auto-ignition temperature: Decomposition temperature: SADT: Viscosity, dynamic: Viscosity, kinematic: VOC: No data available. 1.02 Insoluble PARTIAL IN TOLUENE No data available. No data available. No data available. No data available. No data available. No data available. 27 g/l 10.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Skin Contact: No data available. Eye contact: No data available. Information on toxicological effects Acute toxicity (list all possible routes of exposure) Oral Product: Specified substance(s): Hexamethyldisilazane No data available.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Serious Eye Damage/Eye Irritation Product: No data available. Specified substance(s): TITANIUM DIOXIDE No eye irritation Respiratory or Skin Sensitization Product: No data available. Specified substance(s): TITANIUM DIOXIDE Carcinogenicity Product: negative No data available. IARC Monographs on the Evaluation of Carcinogenic Risks to Humans: TITANIUM DIOXIDE Overall evaluation: 2B. Possibly carcinogenic to humans. US.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Aspiration Hazard Product: Other effects: No data available. Contains dibutyltin compound(s) - May impair fertility. May cause harm to unborn child. 12. Ecological information Ecotoxicity: Acute hazards to the aquatic environment: Fish Product: Specified substance(s): TITANIUM DIOXIDE Silica Aquatic Invertebrates Product: No data available. LC0 (Leuciscus idus, 48 h): > 1,000 mg/l LC0 (Brachydanio rerio, 96 h): 5,000 mg/l No data available.
Version: 1.10 Revision Date: 07/28/2016 GE5010 TITANIUM DIOXIDE BOD/COD Ratio Product: 0% No data available. Bioaccumulative Potential Bioconcentration Factor (BCF) Product: No data available. Partition Coefficient n-octanol / water (log Kow) Product: No data available. Mobility in Soil: No data available. Known or predicted distribution to environmental compartments Distillates, petroleum, No data available. hydrotreated middle Hexamethyldisilazane No data available.
Version: 1.10 Revision Date: 07/28/2016 GE5010 IMDG Not regulated. IATA Not regulated. Special precautions for user: This product is not regarded as dangerous goods according to the national and international regulations on the transport of dangerous goods. 15. Regulatory information US Federal Regulations TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D) None present or none present in regulated quantities. CERCLA Hazardous Substance List (40 CFR 302.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Clean Water Act Section 311 Hazardous Substances (40 CFR 117.3) None present or none present in regulated quantities. Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130): None present or none present in regulated quantities. US State Regulations US. California Proposition 65 This product contains chemical(s) known to the State of California to cause cancer and/or to cause birth defects or other reproductive harm.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Inventory Status: Australia AICS: Canada DSL Inventory List: EU EINECS List: Japan (ENCS) List: China Inventory of Existing Chemical Substances: Korea Existing Chemicals Inv. (KECI): Canada NDSL Inventory: Philippines PICCS: US TSCA Inventory: New Zealand Inventory of Chemicals: Taiwan. Taiwan inventory (CSNN): n (Negative listing) y (positive listing) y (positive listing) n (Negative listing) y (positive listing) Remarks: None. Remarks: None. Remarks: None.
Version: 1.10 Revision Date: 07/28/2016 GE5010 Disclaimer: Notice to reader Unless otherwise specified in section 1, Momentive products are intended for use in the manufacture and/or formulation of products and are not intended for direct consumer use. These products are not intended for long-lasting (> 30 days) implantation, injection or direct ingestion into the human body, nor for use in the manufacture of multiple use contraceptives. Keep out of the reach of children.