Installation Guide
5 6
Connect AC line to black, white and green wires
from Lutron interface with twist-on wire caps.
Connect EcoSystem bus wires to the two purple
Lutron connectors (Link E1 and E2).
After completing connections, replace enclosure
cover and screw down M4 screws and lock washers.
Make sure screws are tight and cover is secured.
E1 and E2
Single unit installation scenario:
Multiple units in series installation scenario:
Luminaire
1179mm (46.4 in.)
(distance between canopy sets)
Canopy set
Distance between canopy sets for left and right luminaires = 1193mm (47 in.)
Distance between canopy sets for luminaires in the middle = 1207mm (47.5 in.)
Example: To install ve units in series, the distance between canopy sets for the 1st (left) and 5th (right) luminaire is
1193mm (47 in.), and the distance between canopy sets for the 2nd, 3rd and 4th (middle) luminaires is 1207mm (47.5 in.).
Dene Distance Between Canopy Sets
1st luminaire 2nd luminaire 3rd luminaire 4th luminaire 5th luminaire
1193mm (47 in.) 1207mm (47.5 in.) 1207mm (47.5 in.) 1207mm (47.5 in.) 1193mm (47 in.)