Installation Guide

Wiring Diagram
Electrical Connections
Lutron Interface
0-10V
Output
GND
N
Switched Hot/Out
Constant Hot/In
EcoSystem
Digital Link
PSU
FIXTURE
Line
Neutral
DALI
DALI/0-10V
0-10V
Red
Black
Red
White
Violet
White
White
Blue
Black
Grey
Orange
Black
+
+
GND (Green-Yellow)
Neutral (White)
Line (Black)
EcoSystem Link E1
EcoSystem Link E2
AC line
Violet/White
21
Gently place enclosure cover close to the driver
enclosure. Follow wiring diagram and insert striped
wires into Lutron interface connector as described
in next step.
Carefully unpack unit from its packaging. Install
driver enclosure to a suitable structural member
using two ¼-20 screws.
Risk of damage: Make sure driver enclosure is not
installed where wires can be cut by sharp edges.
a) Grey
b) Violet
c) Green-yellow
AC line
EcoSystem line
Black
e) Orange
d) White
3 4
Connect Driver wires to Lutron interface as follows:
a) Driver 0-10V grey wire to Lutron grey connector.
b) Driver 0-10V violet wire to Lutron violet connector.
c) One green-yellow wire to Lutron green connector.
d) One Driver white wire to Lutron white connector.
e) Driver orange wire to Lutron orange connector.
Push out appropriate size knockout tabs and install
approved conduit connectors for both the AC and
EcoSystem lines.
1/4-20 screws