Specification Sheet
GE Oil & Gas
16240 Port Northwest Dr., Suite 100
Houston, Texas 77041-2645
Inside US Ph: 800.521.1114
Inside US Fax: 800.335.5224
Outside US Ph: +1 832.590.2303
Outside US Fax: +1 832.590.2494
Email: rootsmeters.inquiries@ge.com
Visit us online at:
www.ge.com/energy
© 2012 General Electric Company
All Rights Reserved
*Denotes trademarks of General
Electric Company
GEA19164_Dresser Micro Corrector_IMC/W2
Rev. 9.2012
Ordering Information
The IMC/W2 with or without DP can be ordered
as either:
■
An integral part of a new meter.
■
As a kit to convert existing Dresser Series-A (LMMA),
Series-B (TQM), or Romet meters.
For P and PTZ versions
The IMC/W2 is available in the following pressure
transducer ranges:
Pressure Piping Kits for Non-DP versions
■
The 350 psi (24 bar), 1000 psi (70 bar), and 1500 psi
(100 bar) transducers would typically be used for
high pressure meter applications
■
The IMC/W2 can be ordered with either an external
or internal pressure connection
■
IMC/W2’s for Series-A meters, 23M - 56M high
capacity meters, and high pressure meters require
external pressure connections
■
Optional piping kits are available for convenient
connection of external pressure connections
Transducer Range Gauge Absolute
30 psi (2bar) X X
180 psi (12 bar) X X
350 psi (24 bar) X
1000 psi (70 bar) X X
1500 psi (100 bar) X
For PTZ and T versions
■
All 23M - 56M high capacity meters, and high pressure
meters require an external temperature probe and
thermowell.
The probes are available with 5 ft or 10 ft
armored cables and in 2” or 8-1/2” in insertion lengths
■
Thermowells are available in sizes 1/4-NPT x 2, 1-NPT x
2, 1-NPT x 4, and 1-NPT x 6; all dimensions are in inches
A variety of pulse output connectors are available
■
Metal 6-pin circular twist lock connectors
■
Plastic cable-gland connectors
■
Conduit fittings and other special connectors are
available upon request
The IMC/W2 will be shipped with a factory standard
configuration unless the customer specifies otherwise.
A sealed battery pack is included and provides a nominal
5 years of reliable corrector operation. Adding the
optional Micro Generator may extend battery life to
7 years or more.
New users will want to order the user terminal software
and one or more communication cables to allow local
configuration, calibration, and data retrieval. The cables
are available in 6, 25, and 50 ft. lengths. Special cables
are available for proving the meter and corrector with
the Dresser Model-5 Transfer Prover. See TS: Dresser
SmartProve for further details.
■
For IMC/W2-dp version, the following piping kits
are available:
Length of SS Tubing Part Number
36” 051416-600
36” with Pipe Plugs 051416-610
36” with Test Plugs 051416-620
Communication Cables
PC (Serial) to IMC
Length of Cable Part Number
6.6’ 057135-001
25’ 057135-002
50’ 057135-003
PC (USB) to IMC
6.4’ 060506-000
Approved for use
to 350 psig G
Approved for use to
1480 psig G
Length of SS Tubing Part Number Part Number
32” 051416-320 051416-310
84” 051416-420 051416-410
120” 051416-520 051416-510
Circular Conduit Plug
Cable Gland
Battery Packs
Sealed Alkaline Pack - P/N 055362-000
Sealed Lithium Pack - P/N 060587-000