Data Sheet

2008/I-13
GE Lighting Solutions 1-888-MY-GE-LED www.gelightingsolutions.com
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
DGE DURAGLOW
® 400 LUMINAIRE
NUVATION
Electronic Ballast
High Bay, Open – Optical Sliding Disconnect Series
® Registered Trademark of General Electric Company
TM
Trademark of General Electric Company
Data subject to change without notice
FIXTURE DIMENSIONS
DATA
Approximate Net Weight lbs kgs
Ballast and Optical 16 - 31 7 - 14
DIMENSIONS
When optical assembly contains a quartz socket an additional 
1.125 inches (29mm) must be added to the overall height due to 
double stack disconnect.
NOTES
See explanation on “Optical Flexibility” Page I-4. See References.
REFERENCES
See Page I-104 for start of Accessories.
See Page I-117 for Component Ordering Logic.
See Page I-129 for Explanation of Options and Other Terms Used.
15.00 in. Dia.
(381mm)
3/4 in. NPSC
Thread
Fixture Height
V7 - 30.00 in.
(762mm)
V2 - 30.187 in.
(767mm)
V7 - 17.13 in. Dia. (434mm)
V2 - 22.80 in. Dia. (579mm)
BALLAST DATA
*  13% Improvement in Pulse Start Metal Halide lamp lumen maintenance vs. magnetic.
*   6% improvement in Ceramic Metal Halide lamp lumen maintenance vs. magnetic.
*   50% lower ballast losses than typical CWA magnetic HID ballast.
*   Lamp wattage regulation of +/-2% change for +/-10% change in line voltage.
*   Ballast is rated for use with voltage range between 208 and 277 with +/-10% line voltage tolerance, 50/60 Hz, and will 
automatically sense voltage within specied range.
*   Ballast input current total harmonic distortion (THD) of less than 15% when operated at nominal line voltage.
*   Ballast is thermally protected to shut o when operating temperatures are
above unacceptable levels for the ballast safe and reliable operation.
*   Ballast has an end-of-lamp-life detection and shutdown circuit.
*  The ballast shall have a minimum starting temperature of –20 degrees F 
and maximum operating ambient of 55 degrees C..
*   Ballast is capable of operating pulse start metal halide or ceramic metal halide lamp types.
*   Five-Year Fixture Failure Warranty.
*   Meets requirements of FCC rules and regulations, Title 47 CFR part 18 for nonconsumer equipment.
Dimming Ballast
*   The ballast is supplied with a violet (+) and gray (-) wire for dimming control connections.
*   Ballast dims to fty percent of rated lamp wattage.
*   Dimming voltage is  0-10V where 10V is high wattage and 0 is fty percent of rated lamp wattage.
* Ballast operates the lamp at high wattage for 15 minutes at start up.
* Ballast operates lamp at high wattage for fteen minutes after operating in dim mode for twenty-four hours.
Lamp Line Input
Wattage Voltage Watts
400 277 428
400 240 432
400 208 435
350 277 377
350 240 380
350 208 383
320 277 346
320 240 347
320 208 349
250 277 276
250 240 272
250 208 271
INPUT WATTAGE TABLE